Impact of Preprocessing Parameters in Medical Imaging-Based Radiomic Studies: A Systematic Review
Cancers · 26.07.2024 · 16 (15) · 2668
DOI: 10.3390/cancers16152668 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Cancers, online erschienen am 26.07.2024. Verfasst von Valeria Trojani und 3 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics, Azienda USL-IRCCS, 42123 Reggio Emilia, Italy. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 97 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of Health—Ricerca Corrente Annual Program 2025.
Abstract (Originalsprache)
Background
Lately, radiomic studies featuring the development of a signature to use in prediction models in diagnosis or prognosis outcomes have been increasingly published. While the results are shown to be promising, these studies still have many pitfalls and limitations. One of the main issues of these studies is that radiomic features depend on how the images are preprocessed before their computation. Since, in widely known and used software for radiomic features calculation, it is possible to set these preprocessing parameters before the calculation of the radiomic feature, there are ongoing studies assessing the stability and repeatability of radiomic features to find the most suitable preprocessing parameters for every used imaging modality. Materials and Methods: We performed a comprehensive literature search using four electronic databases: PubMed, Cochrane Library, Embase, and Scopus. Mesh terms and free text were modeled in search strategies for databases. The inclusion criteria were studies where preprocessing parameters’ influence on feature values and model predictions was addressed. Records lacking information on image acquisition parameters were excluded, and any eligible studies with full-text versions were included in the review process, while conference proceedings and monographs were disregarded. We used the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool to investigate the risk of bias. We synthesized our data in a table divided by the imaging modalities subgroups.
Results
After applying the inclusion and exclusion criteria, we selected 43 works. This review examines the impact of preprocessing parameters on the reproducibility and reliability of radiomic features extracted from multimodality imaging (CT, MRI, CBCT, and PET/CT). Standardized preprocessing is crucial for consistent radiomic feature extraction. Key preprocessing steps include voxel resampling, normalization, and discretization, which influence feature robustness and reproducibility. In total, 44% of the included works studied the effects of an isotropic voxel resampling, and most studies opted to employ a discretization strategy. From 2021, several studies started selecting the best set of preprocessing parameters based on models’ best performance. As for comparison metrics, ICC was the most used in MRI studies in 58% of the screened works.
Conclusions
From our work, we highlighted the need to harmonize the use of preprocessing parameters and their values, especially in light of future studies of prospective studies, which are still lacking in the current literature.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Physics, Azienda USL-IRCCS, 42123 Reggio Emilia, Italy.
- Medical Library, Azienda USL-IRCCS, 42123 Reggio Emilia, Italy.
ORCID-Profile: Valeria Trojani, Maria Chiara Bassi, Laura Verzellesi, Marco Bertolini
Förderung
- Italian Ministry of Health—Ricerca Corrente Annual Program 2025
Zitieren
APA
Trojani, V., Bassi, M. C., Verzellesi, L., & Bertolini, M. (2024). Impact of Preprocessing Parameters in Medical Imaging-Based Radiomic Studies: A Systematic Review. Cancers, 16(15), 2668. https://doi.org/10.3390/cancers16152668
Vancouver
Trojani V, Bassi MC, Verzellesi L, Bertolini M. Impact of Preprocessing Parameters in Medical Imaging-Based Radiomic Studies: A Systematic Review. Cancers. 2024;16(15):2668. doi:10.3390/cancers16152668
BibTeX
@article{Trojani2024,
author = {Trojani, Valeria and Bassi, Maria Chiara and Verzellesi, Laura and Bertolini, Marco},
title = {Impact of Preprocessing Parameters in Medical Imaging-Based Radiomic Studies: A Systematic Review},
journal = {Cancers},
year = {2024},
volume = {16},
number = {15},
pages = {2668},
doi = {10.3390/cancers16152668}
}