Magnetic resonance imaging radiomic features stability in brain metastases: Impact of image preprocessing, image-, and feature-level harmonization
Physics and Imaging in Radiation Oncology · 2024-04 · 30 · 100585
DOI: 10.1016/j.phro.2024.100585 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics and Imaging in Radiation Oncology, 2024-04. Verfasst von Zahra Khodabakhshi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Zurich, Switzerland. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background and purpose: Magnetic resonance imaging (MRI) scans are highly sensitive to acquisition and reconstruction parameters which affect feature stability and model generalizability in radiomic research. This work aims to investigate the effect of image pre-processing and harmonization methods on the stability of brain MRI radiomic features and the prediction performance of radiomic models in patients with brain metastases (BMs). Materials and methods: Two T1 contrast enhanced brain MRI data-sets were used in this study. The first contained 25 BMs patients with scans at two different time points and was used for features stability analysis. The effect of gray level discretization (GLD), intensity normalization (Z-score, Nyul, WhiteStripe, and in house-developed method named N-Peaks), and ComBat harmonization on features stability was investigated and features with intraclass correlation coefficient >0.8 were considered as stable. The second data-set containing 64 BMs patients was used for a classification task to investigate the informativeness of stable features and the effects of harmonization methods on radiomic model performance.
Results
Applying fixed bin number (FBN) GLD, resulted in higher number of stable features compare to fixed bin size (FBS) discretization (10 ± 5.5 % higher). `Harmonization in feature domain improved the stability for non-normalized and normalized images with Z-score and WhiteStripe methods. For the classification task, keeping the stable features resulted in good performance only for normalized images with N-Peaks along with FBS discretization.
Conclusions
To develop a robust MRI based radiomic model we recommend using an intensity normalization method based on a reference tissue (e.g N-Peaks) and then using FBS discretization.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Zitieren
APA
Khodabakhshi, Z., Gabrys, H., Wallimann, P., Guckenberger, M., Andratschke, N., & Tanadini-Lang, S. (2024). Magnetic resonance imaging radiomic features stability in brain metastases: Impact of image preprocessing, image-, and feature-level harmonization. Physics and Imaging in Radiation Oncology, 30, 100585. https://doi.org/10.1016/j.phro.2024.100585
Vancouver
Khodabakhshi Z, Gabrys H, Wallimann P, Guckenberger M, Andratschke N, Tanadini-Lang S. Magnetic resonance imaging radiomic features stability in brain metastases: Impact of image preprocessing, image-, and feature-level harmonization. Physics and Imaging in Radiation Oncology. 2024;30:100585. doi:10.1016/j.phro.2024.100585
BibTeX
@article{Khodabakhshi2024,
author = {Khodabakhshi, Zahra and Gabrys, Hubert and Wallimann, Philipp and Guckenberger, Matthias and Andratschke, Nicolaus and Tanadini-Lang, Stephanie},
title = {Magnetic resonance imaging radiomic features stability in brain metastases: Impact of image preprocessing, image-, and feature-level harmonization},
journal = {Physics and Imaging in Radiation Oncology},
year = {2024},
volume = {30},
pages = {100585},
doi = {10.1016/j.phro.2024.100585}
}