EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Assessment of Beam Configurations on the Embodied Carbon and Cost of Reinforced Concrete Two-Way Joist Slab Systems

Chia Paknahad, Mosleh Tohidi, Ali Bahadori-Jahromi

Buildings · 16.04.2026 · 16 (8) · 1578

DOI: 10.3390/buildings16081578 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 16.04.2026. Verfasst von Chia Paknahad und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The literature identifies concrete and steel as the primary contributors to embodied carbon in building structures and highlights a strong relationship between sustainability and structural system geometry. However, existing studies predominantly focus on one-way systems and flat slabs, while research on two-way joist slabs remains limited and often centred on strength optimisation. In particular, there is a lack of systematic life cycle comparisons of alternative beam configurations within this system. This gap is critical, as early-stage design decisions largely determine the environmental impact of structural systems. This study presents a comprehensive, span-dependent evaluation of four beam configurations, namely Without Beam, Internal Beam, Perimeter Beam, and Full Beam, for reinforced concrete two-way joist slabs used in office buildings. A parametric framework was developed using Eurocode-compliant structural design and nonlinear finite element modelling to assess 36 span combinations ranging from 4 × 4 m to 14 × 14 m. Material quantities were extracted from the final designs and converted into embodied carbon values using cradle-to-gate (A1–A3) emission factors derived from the ICE database. The results demonstrate that beam configuration has a significant influence on embodied carbon and construction cost. For spans below approximately 8 m, beamless systems provide the most material-efficient solution. For spans exceeding approximately 10 m, full-beam configurations offer improved structural efficiency and reduced embodied carbon due to enhanced stiffness and load distribution.

Zitieren

APA

Paknahad, C., Tohidi, M., & Bahadori-Jahromi, A. (2026). Comparative Assessment of Beam Configurations on the Embodied Carbon and Cost of Reinforced Concrete Two-Way Joist Slab Systems. Buildings, 16(8), 1578. https://doi.org/10.3390/buildings16081578

Vancouver

Paknahad C, Tohidi M, Bahadori-Jahromi A. Comparative Assessment of Beam Configurations on the Embodied Carbon and Cost of Reinforced Concrete Two-Way Joist Slab Systems. Buildings. 2026;16(8):1578. doi:10.3390/buildings16081578

BibTeX
@article{Paknahad2026,
  author = {Paknahad, Chia and Tohidi, Mosleh and Bahadori-Jahromi, Ali},
  title = {Comparative Assessment of Beam Configurations on the Embodied Carbon and Cost of Reinforced Concrete Two-Way Joist Slab Systems},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {8},
  pages = {1578},
  doi = {10.3390/buildings16081578}
}
Kostenlos starten →