Quantifying Shear Wall Quantity for Seismic Design Practice of Reinforced Concrete Buildings with One-Way Joist Slabs
Buildings · 25.04.2026 · 16 (9) · 1684
DOI: 10.3390/buildings16091684 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 25.04.2026. Verfasst von Umut Hasgul und 1 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
One-way joist slab floor systems are commonly favored in modern residential building applications due to their efficiency in architectural and structural design processes. However, a significant number of such buildings experienced heavy damage or collapse mechanisms during the catastrophic earthquakes in Türkiye since they are more vulnerable due to some uncertainties in the design and construction stages. In this regard, although well-known seismic codes such as Eurocode, IBC, and ASCE do not impose additional requirements for the design of structural systems with joist slabs, the seismic codes of some Mediterranean basin countries regulate the ductility levels, use of shear walls, and member/system-based specific requirements. In the present study, the impact of shear wall quantity on the seismic behavior of reinforced concrete buildings with one-way joist slabs was investigated in five-story structural systems, which were basically similar in terms of the slab properties and layout but have different overturning moment ratios (αM = 0.75, 0.60, 0.45, 0). In this context, a total of 88 bi-directional nonlinear time history analyses were conducted on four structural systems, which were highly representative of buildings in the earthquake zones of Türkiye, under real earthquake ground motions. Hence, the seismic behavior demands—including story displacement, inter-story drift and plastic deformations, distributions of plastic hinges, and member-based performance levels—were discussed by the overturning moment ratio that is directly associated with the shear wall quantity in the system. It can be concluded that when these buildings are jointly designed with the shear walls and frames of a high ductility level—through the capacity design principles—the stipulated performance objective can be successfully achieved. While the shear wall quantities ranging from 0.45 to 0.75 did not have a significant impact on the member-based damage across all floors, the frame-only system was found to be inadequate for controlling the lateral deformations due to insufficient stiffness under design-based seismic events.
Zitieren
APA
Hasgul, U., & Kurt, M. S. (2026). Quantifying Shear Wall Quantity for Seismic Design Practice of Reinforced Concrete Buildings with One-Way Joist Slabs. Buildings, 16(9), 1684. https://doi.org/10.3390/buildings16091684
Vancouver
Hasgul U, Kurt MS. Quantifying Shear Wall Quantity for Seismic Design Practice of Reinforced Concrete Buildings with One-Way Joist Slabs. Buildings. 2026;16(9):1684. doi:10.3390/buildings16091684
BibTeX
@article{Hasgul2026,
author = {Hasgul, Umut and Kurt, Mehmet Seref},
title = {Quantifying Shear Wall Quantity for Seismic Design Practice of Reinforced Concrete Buildings with One-Way Joist Slabs},
journal = {Buildings},
year = {2026},
volume = {16},
number = {9},
pages = {1684},
doi = {10.3390/buildings16091684}
}