Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars
Buildings · 20.08.2023 · 13 (8) · 2106
DOI: 10.3390/buildings13082106 ↗Kurz gefasst
Fachartikel in der Zeitschrift Buildings, online erschienen am 20.08.2023. Verfasst von Amirhassan Alizadeh und 4 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Shear failure is an unfavorable phenomenon as it is a brittle type of failure; however, adding rebars and fibers to a concrete beam can minimize its detrimental effects. The objective of this study was to experimentally investigate the shear behavior of high-strength concrete (HC) beams reinforced with hooked-end (H) steel fibers and high-strength steel (HS) rebars under three-point bending tests. For this purpose, nine HC beams (300 × 250 × 1150 mm in dimension) were cast with 0%, 1%, and 2% H fibers by volume in three longitudinal rebar ratios (i.e., 1.5%, 2.0%, and 3.1%) and compared with beams without fibers. Furthermore, numerical analyses were performed to validate the experimental results and compare them with design codes. The results showed that, irrespective of the fiber content or longitudinal rebar ratio, the beams failed in shear. Increasing the rebar ratio and fiber content increased the shear capacity to as high as 100% (for the specimen with 3% rebar and 2% fiber compared to its counterpart with 1% rebar and 2% fiber). In addition, the research-based equations proposed in the literature either overestimated or underestimated the shear capacity of fibrous HC beams significantly. The level of overestimation or underestimation was closely related to the sensitivity of the proposed model to the shear span ratio and the fiber content. Rebars proved to be more beneficial in contributing to the shear capacity, but the rate of this positive contribution decreased as the fiber ratio increased. Finally, the inverse analysis approach adopted herein proved to be an efficient tool in estimating the shear response of fiber-reinforced beams failing in shear (margin of error: less than 10%).
Zitieren
APA
Alizadeh, A., Shaghaghi, T. M., Pourbaba, M., Mirrezaei, S. S., & Zandi, Y. (2023). Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars. Buildings, 13(8), 2106. https://doi.org/10.3390/buildings13082106
Vancouver
Alizadeh A, Shaghaghi TM, Pourbaba M, Mirrezaei SS, Zandi Y. Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars. Buildings. 2023;13(8):2106. doi:10.3390/buildings13082106
BibTeX
@article{Alizadeh2023,
author = {Alizadeh, Amirhassan and Shaghaghi, Taleb Moradi and Pourbaba, Masoud and Mirrezaei, Seyed Saeed and Zandi, Yousef},
title = {Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars},
journal = {Buildings},
year = {2023},
volume = {13},
number = {8},
pages = {2106},
doi = {10.3390/buildings13082106}
}