EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

MRI Visibility and MR–DSA Concordance of the Nuvascular Harbor Intrasaccular Occlusion Device: A Preclinical Study

Gökce Hatipoglu Majernik, Andreas Öllerer iD, Teresa Lassacher, Emre Kaya iD, Dzmitry Kuzmin iD, Andrea Janu iD, Christoph Griessenauer, Monika Killer-Oberpfalzer

Brain Sciences · 25.03.2026 · 16 (4) · 348

DOI: 10.3390/brainsci16040348 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brain Sciences, online erschienen am 25.03.2026. Verfasst von Gökce Hatipoglu Majernik und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Paracelsus Medical University, Christian Doppler Clinic, 5020 Salzburg, Austria. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nuvascular Inc..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: This GLP (Good laboratory practice) study evaluates the MRI compatibility and occlusion performance of the Nuvascular Harbor intrasaccular device for the treatment of bifurcation and sidewall aneurysms in a rabbit aneurysm model.

Methods

A total of 27 New Zealand White rabbits with 33 surgically created aneurysms (22 bifurcation, 11 side wall) were included and allocated to 90-day (n = 12) or 180-day (n = 15) follow-up. After exclusion of one aneurysm due to parent vessel occlusion and one aneurysm unsuitable for treatment, 31 treated aneurysms remained for analysis. All animals underwent DSA and 3T MRI, including TOF-MRA, FLAIR, DWI, and SWI sequences. Occlusion status was independently graded using the Raymond–Roy Occlusion Classification (RROC), and intermodality agreement was assessed.

Results

MR-based occlusion assessment demonstrated strong agreement with DSA, with exact Raymond–Roy class concordance in 80.6% of cases and clinically relevant agreement (adequate vs. incomplete occlusion) in 96.8%. Agreement analysis showed substantial concordance (Cohen’s κ = 0.65) and a strong positive correlation (r = 0.79). Adequate occlusion rates were comparable between modalities (87.1% on MRA vs. 83.9% on DSA), supporting the reliability of MR imaging for non-invasive occlusion assessment, reflecting consistent device visibility on MR imaging.

Conclusions

The Harbor device provides a promising solution for follow up aneurysm occlusion with increased MR visibility, enabling safer, contrast- and radiation-free follow-up. This study emphasizes the need for future endovascular devices to integrate imaging compatibility into their design to enhance long-term patient follow up.

Schlagwörter

Stichwörter der Autor:innen

MR visibilityaneurysmsintrasaccular device

Autor:innen und Institutionen

  • Department of Neurosurgery, Paracelsus Medical University, Christian Doppler Clinic, 5020 Salzburg, Austria.
  • Institute of Neurointervention, Paracelsus Medical University, Christian Doppler Clinic, 5020 Salzburg, Austria.
  • Department of Neuroradiology, Paracelsus Medical University, Christian Doppler Clinic, 5020 Salzburg, Austria.
  • Department of Minimally Invasive Neurosurgery, Hospital Burgenland, 7400 Oberwart, Austria.
  • Department of Neurology, Paracelsus Medical University, Christian Doppler Clinic, 5020 Salzburg, Austria.

ORCID-Profile: Andreas Öllerer, Emre Kaya, Dzmitry Kuzmin, Andrea Janu

Förderung

  • Nuvascular Inc.

Zitieren

APA

Hatipoglu Majernik, G., Öllerer, A., Lassacher, T., Kaya, E., Kuzmin, D., Janu, A., Griessenauer, C., & Killer-Oberpfalzer, M. (2026). MRI Visibility and MR–DSA Concordance of the Nuvascular Harbor Intrasaccular Occlusion Device: A Preclinical Study. Brain Sciences, 16(4), 348. https://doi.org/10.3390/brainsci16040348

Vancouver

Hatipoglu Majernik G, Öllerer A, Lassacher T, Kaya E, Kuzmin D, Janu A, et al. MRI Visibility and MR–DSA Concordance of the Nuvascular Harbor Intrasaccular Occlusion Device: A Preclinical Study. Brain Sciences. 2026;16(4):348. doi:10.3390/brainsci16040348

BibTeX
@article{HatipogluMajernik2026,
  author = {Hatipoglu Majernik, Gökce and Öllerer, Andreas and Lassacher, Teresa and Kaya, Emre and Kuzmin, Dzmitry and Janu, Andrea and Griessenauer, Christoph and Killer-Oberpfalzer, Monika},
  title = {MRI Visibility and MR–DSA Concordance of the Nuvascular Harbor Intrasaccular Occlusion Device: A Preclinical Study},
  journal = {Brain Sciences},
  year = {2026},
  volume = {16},
  number = {4},
  pages = {348},
  doi = {10.3390/brainsci16040348}
}
Kostenlos starten →