Fachartikel in der Zeitschrift American Journal of Neuroradiology, online erschienen am 13.11.2026. Verfasst von Fernanda Rodriguez-Erazú und 10 weiteren Autor:innen. Beteiligte Einrichtung: From the Lyerly Neurosurgery (F.R.-E., R.A.H., O.F.D.T., S.F.G.-A.), Baptist Neurological Institute, Jacksonville, Florida, USA; Jacksonville Univers….
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: Virtual simulation is increasingly promoted for intrasaccular device sizing, but whether it changes device selection or procedural outcomes for new, highly conformable devices is unknown. We compared Sim&Size simulation with instructions-for-use (IFU) chart sizing for the Artisse 2.0 in early multicenter experience. MATERIALS AND METHODS: We retrospectively analyzed data from the INSPIRE-A registry (November 2022-June 2024). Sim&Size use depended on software availability. We assessed agreement between sizing tools, technical success, first-device success, adjunctive devices, procedure and fluoroscopy times, complications, and the cause of each technical failure. RESULTS: Sim&Size was used in 88/123 cases (71.5%). When both methods were used (n=59), the same device was selected in 54 (91.5%). Technical success was 98.9% with Sim&Size and 85.7% without (p=0.007), whereas first-device success (86.4% vs 80.0%, p=0.41) and procedure and fluoroscopy times did not differ. Perioperative complications occurred in 4/123 (3.3%). Of the six technical failures, five were related to device fit, mostly in anatomies at the limits of the device range, and one resulted from a perforation before deployment. A dome-to-neck ratio
Autor:innen und Institutionen
- From the Lyerly Neurosurgery (F.R.-E., R.A.H., O.F.D.T., S.F.G.-A.), Baptist Neurological Institute, Jacksonville, Florida, USA; Jacksonville University (F.R.-E., O.F.D.T., S.F.G.-A.), Research Department 4121 Jacksonvi…
Zitieren
APA
Rodriguez-Erazú, F., Hanel, R. A., de Toledo, O. F., Gutierrez-Aguirre, S. F., Cortese, J., Möhlenbruch, M. A., Lamin, S., Rautio, R., Fiehler, J., Spelle, L., & Killer-Oberpfalzer, M. (2026). Sim&Size versus IFU-Based Sizing for the Artisse 2.0 Intrasaccular Device in a Multicenter Registry. American Journal of Neuroradiology, ajnr.A9716. https://doi.org/10.3174/ajnr.a9716
Vancouver
Rodriguez-Erazú F, Hanel RA, de Toledo OF, Gutierrez-Aguirre SF, Cortese J, Möhlenbruch MA, et al. Sim&Size versus IFU-Based Sizing for the Artisse 2.0 Intrasaccular Device in a Multicenter Registry. American Journal of Neuroradiology. 2026:ajnr.A9716. doi:10.3174/ajnr.a9716
BibTeX
@article{RodriguezEraz2026,
author = {Rodriguez-Erazú, Fernanda and Hanel, Ricardo A and de Toledo, Otavio F and Gutierrez-Aguirre, Salvador F and Cortese, Jonathan and Möhlenbruch, Markus A and Lamin, Saleh and Rautio, Riitta and Fiehler, Jens and Spelle, Laurent and Killer-Oberpfalzer, Monika},
title = {Sim&Size versus IFU-Based Sizing for the Artisse 2.0 Intrasaccular Device in a Multicenter Registry},
journal = {American Journal of Neuroradiology},
year = {2026},
pages = {ajnr.A9716},
doi = {10.3174/ajnr.a9716}
}
EUVIMED