A PTBD-Based Smart Biliary Stent for Continuous Intrabiliary Pressure Monitoring: Development and In Vivo Feasibility

Jonghyun Lee, Young Woo Kwon, Hye Ji Lee, Sung Hee Park, Hyung Il Seo, Suk Kim, Seung Baek Hong, Sung Yong Han, Dong Uk Kim

Biosensors · 21.11.2026 · 16 (12) · 676

DOI: 10.3390/bios16120676 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 21.11.2026. Verfasst von Jonghyun Lee und 8 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation, Pusan National University Hospital.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biliary stent dysfunction in malignant biliary obstruction remains clinically occult until jaundice or cholangitis develops because current surveillance methods yield no continuous functional information. This study presents a percutaneous transhepatic biliary drainage (PTBD)-based smart biliary stent incorporating a thin-film pressure sensor and evaluates its in vivo feasibility for continuous intrabiliary pressure monitoring. A resistive pressure sensor was fabricated on a liquid-crystal polymer substrate with gold-mesh electrodes encapsulated for bile exposure and integrated into a covered self-expandable metal stent. Following in vitro characterization under bile flow conditions, the device was evaluated in a porcine biliary stricture model created using endoscopic radiofrequency ablation. The sensor lead wire was externalized through a mature PTBD tract. The sensor exhibits a pressure-dependent resistance response and maintains electrical continuity after stent compression and expansion. Of the three animals, one completed the full workflow, from stricture formation to lead-wire externalization, allowing stable continuous pressure recording for approximately 48 h; the in vivo evaluation was therefore based on a single animal. After endoscopic hemoclip-induced distal stent occlusion, the intrabiliary pressure increased from approximately 200 Pa to approximately 3800 Pa within approximately 25 min. These findings provide preliminary evidence for the technical feasibility of PTBD-based smart biliary stent monitoring and suggest that intrabiliary pressure may serve as a real-time physiological indicator of stent dysfunction.

Förderung

  • National Research Foundation
  • Pusan National University Hospital

Zitieren

APA

Lee, J., Kwon, Y. W., Lee, H. J., Park, S. H., Seo, H. I., Kim, S., Hong, S. B., Han, S. Y., & Kim, D. U. (2026). A PTBD-Based Smart Biliary Stent for Continuous Intrabiliary Pressure Monitoring: Development and In Vivo Feasibility. Biosensors, 16(12), 676. https://doi.org/10.3390/bios16120676

Vancouver

Lee J, Kwon YW, Lee HJ, Park SH, Seo HI, Kim S, et al. A PTBD-Based Smart Biliary Stent for Continuous Intrabiliary Pressure Monitoring: Development and In Vivo Feasibility. Biosensors. 2026;16(12):676. doi:10.3390/bios16120676

BibTeX
@article{Lee2026,
  author = {Lee, Jonghyun and Kwon, Young Woo and Lee, Hye Ji and Park, Sung Hee and Seo, Hyung Il and Kim, Suk and Hong, Seung Baek and Han, Sung Yong and Kim, Dong Uk},
  title = {A PTBD-Based Smart Biliary Stent for Continuous Intrabiliary Pressure Monitoring: Development and In Vivo Feasibility},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {12},
  pages = {676},
  doi = {10.3390/bios16120676}
}
Kostenlos starten →