Periodontal Disease Diagnosis by a Chemically Etched Single-Mode Fiber-Optic Biosensor for Label-Free Detection of Matrix Metalloproteinase-8 (MMP-8)
Biosensors · 2026
DOI: 10.3390/bios16090491 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Rigoberto Tovar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Civil Engineering, and Environmental Engineering, U. A. Whitaker College of Engineering, Florida Gulf Coast University,…. Hauptthemen laut MEDLINE: Biosensing Techniques, Matrix Metalloproteinase 8, Periodontal Diseases, Fiber Optic Technology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Head Start Grant from the U. A. Whitaker College of Engineering, Florida Gulf Coast University, 2025-2026., U. A. Whitaker College of Engineering, Florida Gulf Coast University.
Abstract (Originalsprache)
A miniature label-free biosensor based on a chemically etched single-mode optical fiber (SMF) is reported for the detection of matrix metalloproteinase-8 (MMP-8), a salivary biomarker of active periodontitis with a clinical decision threshold of 20 ng/mL. Fibers etched in 48% hydrofluoric acid to a waist diameter of 16.0 ± 1.4 µm gave a mean refractive index (RI) sensitivity of 376.8%/RIU and an RI limit of detection (LOD) of 5.9 × 10−4 RIU. Fibers were tested with MMP-8 spiked into phosphate-buffered saline (PBS) and into saliva over 0–200 ng/mL using a post-rinse protocol with per-fiber matrix subtraction. Dose–responses followed a Langmuir isotherm (Kd = 7.1 ng/mL in PBS, 12.7 ng/mL in saliva), with cohort LODs of 0.043 and 0.52 ng/mL, both well below the threshold. MMP-9 (100 ng/mL) and human serum albumin (1 mg/mL) gave negligible responses (≤2.7%, versus 68.2% for MMP-8 at 100 ng/mL); antibody immobilization was confirmed by confocal immunofluorescence. A commercial sandwich ELISA on the same spike series gave a matched-matrix LOD of 41.1 ng/mL, nearly two orders of magnitude higher. This performance requires no metal coating, nanostructuring, label, or signal amplification, only a single wet-etching step on stock telecommunications fiber.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Bioengineering, Civil Engineering, and Environmental Engineering, U. A. Whitaker College of Engineering, Florida Gulf Coast University, 10501 FGCU Boulevard South, Fort Myers, FL 33965, USA.
- Department of Biomaterials, Biomedical Engineering Corlu Faculty, Tekirdag Namik Kemal University, Yılmaz Alpaslan Cd. No:25, 59850 Tekirdag, Turkey.
ORCID-Profile: Sarkis Sozkes, Marzhan Sypabekova
Förderung
- Head Start Grant from the U. A. Whitaker College of Engineering, Florida Gulf Coast University, 2025-2026.
- U. A. Whitaker College of Engineering, Florida Gulf Coast University
Zitieren
APA
Tovar, R., Sozkes, S., & Sypabekova, M. (2026). Periodontal Disease Diagnosis by a Chemically Etched Single-Mode Fiber-Optic Biosensor for Label-Free Detection of Matrix Metalloproteinase-8 (MMP-8). Biosensors. https://doi.org/10.3390/bios16090491
Vancouver
Tovar R, Sozkes S, Sypabekova M. Periodontal Disease Diagnosis by a Chemically Etched Single-Mode Fiber-Optic Biosensor for Label-Free Detection of Matrix Metalloproteinase-8 (MMP-8). Biosensors. 2026. doi:10.3390/bios16090491
BibTeX
@article{Tovar2026,
author = {Tovar, Rigoberto and Sozkes, Sarkis and Sypabekova, Marzhan},
title = {Periodontal Disease Diagnosis by a Chemically Etched Single-Mode Fiber-Optic Biosensor for Label-Free Detection of Matrix Metalloproteinase-8 (MMP-8)},
journal = {Biosensors},
year = {2026},
doi = {10.3390/bios16090491}
}