EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Optically Silent Epoxysilane Chemistry for Paper-Based ABO Blood Typing

Chinnawut Pipatpanukul iD, Komkrisd Wongtimnoi, Laurent Mezeix, Santi Phosri

Biosensors · 2026

DOI: 10.3390/bios16090468 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Chinnawut Pipatpanukul und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced Materials Engineering, Faculty of Engineering, Burapha University, Chonburi 20131, Thailand. Hauptthemen laut MEDLINE: Silanes, Blood Grouping and Crossmatching, ABO Blood-Group System, Biosensing Techniques. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Burapha University, Faculty of Engineering, Burapha University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Safe transfusion depends on rapid, accurate ABO typing, yet reference methods require centrifuges and instrumentation unavailable at the point of need. Here, a paper-based ABO-RhD typing device built on a covalent, optically silent surface chemistry is reported. Aminosilane (APTES) and epoxysilane (GPTMS) functionalisation of Whatman cellulose was compared by water contact angle, energy-dispersive X-ray spectroscopy (SEM-EDS) and infrared spectroscopy (FT-IR) across two paper grades, three silane concentrations (5, 10 and 20% v/v) and three reaction times (1–6 h). APTES produced a strongly hydrophobic layer that impeded aqueous wicking, and its glutaraldehyde activation generated a red-brick chromophore incompatible with a red-channel readout. GPTMS coupled antibodies in a single mild step, without a crosslinker or visible chromophore, while preserving wicking. GPTMS (10% v/v, 3 h, Whatman No. 4) with a six-cycle 100 µL saline wash was selected; antibodies were immobilised in a four-zone layout (anti-A, anti-B, anti-D and control) within a 3D-printed two-compartment housing that traps agglutinated cells while free cells wash through. On 80 EDTA clinical blood samples (20 each of groups A, B, AB and O) the device classified every sample correctly (accuracy 100%; 95% confidence interval 95.4–100%), with visual and instrumented reads in full agreement. All samples were RhD-positive, so the anti-D channel is validated here for the positive call.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SilanesBlood Grouping and CrossmatchingABO Blood-Group SystemBiosensing TechniquesPaperHumans

Stichwörter der Autor:innen

ABO blood typingantibody immobilisationepoxysilaneglutaraldehyde chromophorepaper-based analytical devicepoint-of-care diagnostics

Substanzen

SilanesABO Blood-Group System

Autor:innen und Institutionen

  • Department of Advanced Materials Engineering, Faculty of Engineering, Burapha University, Chonburi 20131, Thailand.
  • Department of Chemical Engineering, Burapha University, Chonburi 20131, Thailand.

ORCID-Profile: Chinnawut Pipatpanukul

Förderung

  • Burapha University
  • Faculty of Engineering, Burapha University

Zitieren

APA

Pipatpanukul, C., Wongtimnoi, K., Mezeix, L., & Phosri, S. (2026). An Optically Silent Epoxysilane Chemistry for Paper-Based ABO Blood Typing. Biosensors. https://doi.org/10.3390/bios16090468

Vancouver

Pipatpanukul C, Wongtimnoi K, Mezeix L, Phosri S. An Optically Silent Epoxysilane Chemistry for Paper-Based ABO Blood Typing. Biosensors. 2026. doi:10.3390/bios16090468

BibTeX
@article{Pipatpanukul2026,
  author = {Pipatpanukul, Chinnawut and Wongtimnoi, Komkrisd and Mezeix, Laurent and Phosri, Santi},
  title = {An Optically Silent Epoxysilane Chemistry for Paper-Based ABO Blood Typing},
  journal = {Biosensors},
  year = {2026},
  doi = {10.3390/bios16090468}
}
Kostenlos starten →