From Device-Level Implementation to In-Sensor Computing in Memristive-Device-Based Biosensors: A Review
Biosensors · 16.08.2026 · 16 (8) · 444
DOI: 10.3390/bios16080444 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biosensors, online erschienen am 16.08.2026. Verfasst von Hyunwook Ryu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics Engineering, Chungnam National University, Daejeon 34134, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Ministry of Education.
Abstract (Originalsprache)
Memristive devices have attracted considerable attention as promising candidates for overcoming the energy and data-transfer limitations of conventional computing architectures. In particular, their integration with biosensors offers a pathway toward compact and energy-efficient diagnostic systems. This review examines the development of memristive-device-based biosensors from device-level transduction to system-level integration. At the device level, sensing strategies have evolved from direct sensing toward indirect sensing architectures, improving stability and reusability. At the system level, conventional off-chip implementations have progressively shifted toward fully integrated on-chip implementations. Furthermore, this review highlights the emerging paradigm of in-sensor computing, in which sensing, memory, and computation are co-located within a single physical platform. This approach enables reduced data movement and supports energy-efficient operation for point-of-care applications. Finally, key challenges—including CMOS compatibility, device variability, and reliable multi-threshold sensing operation—are discussed as critical factors for the practical realization of memristive-device-based electrochemical biosensing systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics Engineering, Chungnam National University, Daejeon 34134, Republic of Korea.
- Division of Nano Convergence Technology Development, National NanoFab Center (NNFC), Daejeon 34141, Republic of Korea.
- Department of Semiconductor Convergence, Chungnam National University, Daejeon 34134, Republic of Korea.
ORCID-Profile: Won-Chul Lee, Jongwon Lee
Förderung
- National Research Foundation of Korea
- Ministry of Education
Zitieren
APA
Ryu, H., Lee, W. C., & Lee, J. (2026). From Device-Level Implementation to In-Sensor Computing in Memristive-Device-Based Biosensors: A Review. Biosensors, 16(8), 444. https://doi.org/10.3390/bios16080444
Vancouver
Ryu H, Lee WC, Lee J. From Device-Level Implementation to In-Sensor Computing in Memristive-Device-Based Biosensors: A Review. Biosensors. 2026;16(8):444. doi:10.3390/bios16080444
BibTeX
@article{Ryu2026,
author = {Ryu, Hyunwook and Lee, Won-Chul and Lee, Jongwon},
title = {From Device-Level Implementation to In-Sensor Computing in Memristive-Device-Based Biosensors: A Review},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {8},
pages = {444},
doi = {10.3390/bios16080444}
}
EUVIMED