EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Use of Anaerobic Sludge Microbial Consortia in a Microbial Fuel Cell Biosensor for Biochemical Oxygen Demand Measurement

Hebah Altaweel, Jamal Abu-Ashour, Borhan Aldeen Albiss iD, Bassim Abbassi iD

Biosensors · 26.07.2026 · 16 (8) · 406

DOI: 10.3390/bios16080406 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 26.07.2026. Verfasst von Hebah Altaweel und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil Engineering, Jordan University of Science and Technology, Irbid 22110, Jordan. Hauptthemen laut MEDLINE: Bioelectric Energy Sources, Biosensing Techniques, Sewage, Biological Oxygen Demand Analysis. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jordan University of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Effective management of wastewater treatment plants often requires real-time measurements of Biochemical Oxygen Demand (BOD). Conventional methods for determining Biochemical Oxygen Demand (BOD) are often time-consuming, labor-intensive and prone to inaccuracies. Microbial Fuel Cells (MFCs) have emerged as a viable alternative technology for BOD measurement, offering real-time monitoring capability. However, challenges remain in its validity for testing different types of wastewater. This study developed a cost-effective dual-chamber MFC with graphite felt electrodes and a CMI-7000 membrane, inoculated with a microbial consortia grown from anaerobic sludge at optimal conditions (35 °C, pH 7, 1000 Ω external resistance). After one month of biofilm formation, the MFC produced 600 mV. Voltage outputs were measured at six BOD5 concentrations (36 to 583 mg/L) in synthetic wastewater, showing a strong linear correlation between BOD5 concentrations and voltage outputs. The MFC was also tested with five domestic wastewater samples with BOD5 values ranging between 81 and 405 mg/L. The output voltages were inserted into the derived voltage–BOD correlation to obtain BOD5 values within 2.5% to 11% of conventional laboratory results. These findings confirm the potential of MFC-based biosensors as an efficient and accurate tool for real-time wastewater monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bioelectric Energy SourcesBiosensing TechniquesSewageBiological Oxygen Demand AnalysisMicrobial ConsortiaElectrodesWastewaterOxygenAnaerobiosis

Stichwörter der Autor:innen

BODbiosensorelectrogenic bacteriamicrobial fuel cellwastewater monitoring

Substanzen

SewageWastewaterOxygen

Autor:innen und Institutionen

  • Department of Civil Engineering, Jordan University of Science and Technology, Irbid 22110, Jordan.
  • Nanotechnology Institute, Jordan University of Science and Technology, Irbid 22110, Jordan.
  • Department of Civil, Environmental, and Water Resources Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada.

ORCID-Profile: Borhan Aldeen Albiss, Bassim Abbassi

Förderung

  • Jordan University of Science and Technology

Zitieren

APA

Altaweel, H., Abu-Ashour, J., Albiss, B. A., & Abbassi, B. (2026). Use of Anaerobic Sludge Microbial Consortia in a Microbial Fuel Cell Biosensor for Biochemical Oxygen Demand Measurement. Biosensors, 16(8), 406. https://doi.org/10.3390/bios16080406

Vancouver

Altaweel H, Abu-Ashour J, Albiss BA, Abbassi B. Use of Anaerobic Sludge Microbial Consortia in a Microbial Fuel Cell Biosensor for Biochemical Oxygen Demand Measurement. Biosensors. 2026;16(8):406. doi:10.3390/bios16080406

BibTeX
@article{Altaweel2026,
  author = {Altaweel, Hebah and Abu-Ashour, Jamal and Albiss, Borhan Aldeen and Abbassi, Bassim},
  title = {Use of Anaerobic Sludge Microbial Consortia in a Microbial Fuel Cell Biosensor for Biochemical Oxygen Demand Measurement},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {8},
  pages = {406},
  doi = {10.3390/bios16080406}
}
Kostenlos starten →