EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance optimization design for constructed wetland coupled with microbial fuel cell for rural domestic sewage treatment

Tuodi Zhang, Songtao Shen iD, Yingyi Xu

PLOS One · 2026

DOI: 10.1371/journal.pone.0350011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Tuodi Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Environment and Resource, Southwest University of Science and Technology, Mianyang, China. Hauptthemen laut MEDLINE: Wetlands, Sewage, Bioelectric Energy Sources, Water Purification. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Excellent Talent Cultivation Project of Southwest University of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A vertical-flow constructed wetland-microbial fuel cell (CW-MFC) was established with Acorus calamus as the wetland vegetation for rural domestic wastewater treatment under low-temperature winter conditions. Response surface methodology (RSM) coupled with central composite design (CCD) was used to optimize three key electrode parameters: electrode plate projection coefficient (PC), inter-electrode distance (ID), and external resistance (ER), and to evaluate their effects on COD removal efficiency. Compared with the standalone constructed wetland (CW), the CW-MFC system significantly improved wastewater treatment performance: the effluent COD concentration of the CW was 66.14 mg/L, exceeding the first-class discharge limit (60.00 mg/L) specified in the “Water Pollutant Discharge Standard for Rural Domestic Sewage Treatment Facilities” (DB51/2626–2019). In contrast, the effluent COD concentrations of the CW-MFC system ranged from 18.81 to 54.06 mg/L, all meeting the aforementioned first-class standard, with a significantly higher COD removal rate than the CW (P < 0.05). After electrode parameter optimization, the optimal configuration was determined as PC = 0.33, ID = 272.94 mm, and ER = 1619.31 Ω. Under these optimized conditions, the CW-MFC system achieved a COD removal efficiency of 89.14%, which was consistent with the model-predicted value (88.06%) with a deviation of

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WetlandsSewageBioelectric Energy SourcesWater PurificationWaste Disposal, FluidElectrodesWastewaterBiological Oxygen Demand Analysis

Substanzen

SewageWastewater

Autor:innen und Institutionen

  • School of Environment and Resource, Southwest University of Science and Technology, Mianyang, China.
  • School of Culture and Education, Tianfu College of Southwestern University of Finance and Economics, Mianyang, China.

ORCID-Profile: Songtao Shen

Förderung

  • Excellent Talent Cultivation Project of Southwest University of Science and Technology

Zitieren

APA

Zhang, T., Shen, S., & Xu, Y. (2026). Performance optimization design for constructed wetland coupled with microbial fuel cell for rural domestic sewage treatment. PLOS One. https://doi.org/10.1371/journal.pone.0350011

Vancouver

Zhang T, Shen S, Xu Y. Performance optimization design for constructed wetland coupled with microbial fuel cell for rural domestic sewage treatment. PLOS One. 2026. doi:10.1371/journal.pone.0350011

BibTeX
@article{Zhang2026,
  author = {Zhang, Tuodi and Shen, Songtao and Xu, Yingyi},
  title = {Performance optimization design for constructed wetland coupled with microbial fuel cell for rural domestic sewage treatment},
  journal = {PLOS One},
  year = {2026},
  doi = {10.1371/journal.pone.0350011}
}
Kostenlos starten →