An LSPR-Active AuNP–Silicone Hydrogel Contact Lens for Continuous Ocular Strain Sensing: From Engineering Design to In Vivo Validation
Biosensors · 20.05.2026 · 16 (5) · 296
DOI: 10.3390/bios16050296 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 20.05.2026. Verfasst von Yu Tang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China. Hauptthemen laut MEDLINE: Metal Nanoparticles, Surface Plasmon Resonance, Biosensing Techniques, Contact Lenses, Hydrophilic. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Continuous intraocular pressure (IOP) monitoring is crucial for glaucoma management. Currently, traditional static IOP measurements often fail to detect circadian fluctuations, leading to a clinical dilemma where “normal IOP” is observed despite persistent visual field deterioration. This study presents a wireless, passive localized surface plasmon resonance (LSPR) sensing platform integrated into flexible silicone hydrogel contact lenses. Gold nanoparticles (AuNPs), synthesized via the sodium citrate reduction method, were incorporated into the lens periphery using a “swelling-induced nano-doping” technique to transduce IOP-induced corneal strain into detectable spectral shifts. Ex vivo porcine eye investigations established a physical mapping model, confirming significant LSPR peak wavelength response trends in correlation with IOP variations (10–50 mmHg) and corneal curvature changes. Subsequent 21-day in vivo rabbit studies demonstrated excellent ocular surface biocompatibility; quantitative histopathological analysis (HE, PAS, and Ki67 staining) revealed no significant adverse alterations in corneal endothelial cell density or conjunctival goblet cell function compared to control groups (p > 0.05). Furthermore, the platform maintained high structural integrity and anterior segment tolerance under transient high-IOP conditions. While currently a proof-of-concept, these results indicate that the LSPR-active hybrid system effectively captures dynamic IOP fluctuation patterns as an optical response to acute interventions, providing a foundational engineering path for next-generation, battery-free wearable diagnostics in personalized glaucoma care without the need for built-in electronics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, The First Affiliated Hospital of Dalian Medical University, Dalian 116011, China.
- Department of Ophthalmology, Central Hospital of Dalian University of Technology, Dalian 116033, China.
- School of Physics, Dalian University of Technology, Dalian 116024, China.
ORCID-Profile: Yu Tang, Luhua Meng, Yun Liu
Zitieren
APA
Tang, Y., Meng, L., Liu, Y., & Ma, X. (2026). An LSPR-Active AuNP–Silicone Hydrogel Contact Lens for Continuous Ocular Strain Sensing: From Engineering Design to In Vivo Validation. Biosensors, 16(5), 296. https://doi.org/10.3390/bios16050296
Vancouver
Tang Y, Meng L, Liu Y, Ma X. An LSPR-Active AuNP–Silicone Hydrogel Contact Lens for Continuous Ocular Strain Sensing: From Engineering Design to In Vivo Validation. Biosensors. 2026;16(5):296. doi:10.3390/bios16050296
BibTeX
@article{Tang2026,
author = {Tang, Yu and Meng, Luhua and Liu, Yun and Ma, Xiang},
title = {An LSPR-Active AuNP–Silicone Hydrogel Contact Lens for Continuous Ocular Strain Sensing: From Engineering Design to In Vivo Validation},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {5},
pages = {296},
doi = {10.3390/bios16050296}
}
EUVIMED