A closed-loop bioelectronic patch for intelligent blood pressure management
Science Advances · 08.08.2025 · 11 (32)
DOI: 10.1126/sciadv.adx6438 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 08.08.2025. Verfasst von Yuyan Zou und 11 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Provincial Key Laboratory of Micro and Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South Universit…. Hauptthemen laut MEDLINE: Blood Pressure, Blood Pressure Determination. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Cardiovascular diseases remain a leading cause of mortality due to passive and delayed drug interventions. This study introduces an intelligent blood pressure management system (BPMS) for real-time monitoring and adaptive intervention through a closed-loop framework integrating sensors, control circuits, and microneedle electrodes. A hierarchical microneedle architecture, featuring gold nanoparticle (Au NP) electrocatalysts and copper-nitrogen–doped carbon nanoribbon (Cu-NC NB) nanozymes, selectively catalyzes the in situ generation of nitric oxide (NO) for vasodilation. To enhance NO delivery, an electroosmotic flow (EOF) mechanism extends the diffusion range up to 4 millimeters through a porous microneedle (PMN) array, enabling effective vascular penetration. In vivo studies in rabbits and pigs confirm that BPMS dynamically regulates NO release in response to fluctuating blood pressure, achieving real-time hemodynamic control. This work pioneers a closed-loop strategy for continuous blood pressure monitoring and on-demand vasodilation, offering a transformative approach to the intelligent management of cardiovascular diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Hunan Provincial Key Laboratory of Micro and Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan 410083, China.
- Department of Cardiovascular Surgery, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410083, China.
- Institute for Stem Cell and Regenerative Medicine, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China.
- School of Chemistry, Chemical Engineering, and Biotechnology, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore.
ORCID-Profile: Yuyan Zou, Yuqing Li, Wansong Chen, You-Nian Liu, Yanli Zhao
Zitieren
APA
Zou, Y., Chen, Z., Jin, B., Lyu, L., Xie, Y., Li, Y., Zeng, K., Yan, S., Wu, Z., Chen, W., Liu, Y. N., & Zhao, Y. (2025). A closed-loop bioelectronic patch for intelligent blood pressure management. Science Advances, 11(32). https://doi.org/10.1126/sciadv.adx6438
Vancouver
Zou Y, Chen Z, Jin B, Lyu L, Xie Y, Li Y, et al. A closed-loop bioelectronic patch for intelligent blood pressure management. Science Advances. 2025;11(32). doi:10.1126/sciadv.adx6438
BibTeX
@article{Zou2025,
author = {Zou, Yuyan and Chen, Zeguo and Jin, Bowen and Lyu, Linghui and Xie, Yongting and Li, Yuqing and Zeng, Ke and Yan, Siqi and Wu, Zhongshi and Chen, Wansong and Liu, You-Nian and Zhao, Yanli},
title = {A closed-loop bioelectronic patch for intelligent blood pressure management},
journal = {Science Advances},
year = {2025},
volume = {11},
number = {32},
doi = {10.1126/sciadv.adx6438}
}