Multi-Feature Adaptive Variational Mode Decomposition for Wearable ECG Devices
Biosensors · 01.05.2026 · 16 (5) · 262
DOI: 10.3390/bios16050262 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 01.05.2026. Verfasst von Zixin Chen und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic Information, Central South University, Changsha 410083, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Electrocardiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
To address the issue of motion artifact interference faced by wearable ECG monitoring devices in dynamic environments, this paper proposes an adaptive motion artifact removal framework based on improved Variational Mode Decomposition (VMD). By designing a parameter self-adjustment mechanism and a multi-feature fusion mode selection strategy, the algorithm’s adaptability to non-stationary ECG signals and noise separation accuracy are enhanced. Experiments on the MIT-BIH Arrhythmia Database demonstrate that the improved VMD algorithm outperforms traditional wavelet transform, Recursive Least Squares (RLS), and conventional VMD methods in multiple performance metrics. Specifically, the signal-to-noise ratio (SNR) is improved by 5.17 dB, the Percentage Root Mean Squared Difference (PRD) is reduced to 49.13%, the correlation coefficient is increased to 0.88, and high real-time processing capability (Real-Time Processing Ratio, RTR = 22.5) is maintained, meeting the low-latency requirements of wearable devices. Moreover, case studies on pathological recordings (e.g., Wolff–Parkinson–White syndrome and third-degree atrioventricular block) reveal that the improved VMD better preserves clinically significant features such as delta waves and dissociated P waves. Furthermore, a downstream arrhythmia classification task using a CWT-CNN classifier achieves 91.67% accuracy on denoised heartbeats, which is 2.67 percentage points higher than that on raw noisy signals (89.00%), confirming the practical benefit of the proposed preprocessing for AI-based diagnosis. This study provides an effective processing solution for improving the signal quality of wearable ECG monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electronic Information, Central South University, Changsha 410083, China.
- School of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China.
- School of Xiangya Medicine, Central South University, Changsha 410083, China.
ORCID-Profile: Zhengchun Liu
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Chen, Z., Wu, D., Nie, Y., Zhang, J., Liu, G., He, F., Mo, L., Peng, L., Zeng, C., & Liu, Z. (2026). Multi-Feature Adaptive Variational Mode Decomposition for Wearable ECG Devices. Biosensors, 16(5), 262. https://doi.org/10.3390/bios16050262
Vancouver
Chen Z, Wu D, Nie Y, Zhang J, Liu G, He F, et al. Multi-Feature Adaptive Variational Mode Decomposition for Wearable ECG Devices. Biosensors. 2026;16(5):262. doi:10.3390/bios16050262
BibTeX
@article{Chen2026,
author = {Chen, Zixin and Wu, Di and Nie, Yuanlin and Zhang, Junwei and Liu, Guanzhou and He, Feng and Mo, Long and Peng, Liming and Zeng, Chang and Liu, Zhengchun},
title = {Multi-Feature Adaptive Variational Mode Decomposition for Wearable ECG Devices},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {5},
pages = {262},
doi = {10.3390/bios16050262}
}
EUVIMED