EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Frequency-Aware Self-Supervised Framework for MEMS-OCT Denoising

Gaolin Zhang, Zonghao Li, Hui Zhao, Zhe Peng, Huikai Xie iD

Biosensors · 21.03.2026 · 16 (3) · 177

DOI: 10.3390/bios16030177 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 21.03.2026. Verfasst von Gaolin Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing 100081, China. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Micro-Electrical-Mechanical Systems. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Beijing Municipality, the National Science and Technology Planning Project, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical coherence tomography (OCT) is a key biological sensing and imaging tool widely used in biomedical detection, and its images are often degraded by multiplicative speckle noises—especially when micro-electro-mechanical system (MEMS) mirrors are employed in endoscopic OCT imaging, which reduces visual quality and affects the accuracy of subsequent analysis. Traditional denoising algorithms and supervised deep learning approaches have shown some effectiveness, but they are limited by their reliance on paired noisy–clean data and their insufficient modeling of global structural dependencies. To address these issues, this paper proposes a frequency-domain enhanced UNet based on the Neighbor2Neighbor (N2N) framework (FEN2N). The proposed FEN2N integrates wavelet-guided spectral pooling modules (WSPMs) and frequency-domain enhanced receptive field blocks (FE-RFBs). In this work, OCT images are obtained in a self-constructed MEMS-OCT system. Then the FEN2N is applied to the OCT image dataset. Results show that FEN2N achieves a more than 2.3 dB PSNR improvement over the N2N baseline, while the incorporation of FE-RFB contributes to a 0.02 improvement in SSIM. In addition, FEN2N outperforms several state-of-the-art methods, effectively suppressing speckle noise while preserving fine structural details that are important for clinical diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceMicro-Electrical-Mechanical SystemsAlgorithmsSignal-To-Noise RatioImage Processing, Computer-Assisted

Stichwörter der Autor:innen

OCT denoisingfrequency domainself-supervised

Autor:innen und Institutionen

  • School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing 100081, China.
  • LightVision Technologies Inc., Ltd., Foshan 528000, China.
  • BIT Chongqing Institute of Microelectronics and Microsystems, Chongqing 401332, China.

ORCID-Profile: Huikai Xie

Förderung

  • Natural Science Foundation of Beijing Municipality
  • the National Science and Technology Planning Project
  • National Natural Science Foundation of China

Zitieren

APA

Zhang, G., Li, Z., Zhao, H., Peng, Z., & Xie, H. (2026). A Frequency-Aware Self-Supervised Framework for MEMS-OCT Denoising. Biosensors, 16(3), 177. https://doi.org/10.3390/bios16030177

Vancouver

Zhang G, Li Z, Zhao H, Peng Z, Xie H. A Frequency-Aware Self-Supervised Framework for MEMS-OCT Denoising. Biosensors. 2026;16(3):177. doi:10.3390/bios16030177

BibTeX
@article{Zhang2026,
  author = {Zhang, Gaolin and Li, Zonghao and Zhao, Hui and Peng, Zhe and Xie, Huikai},
  title = {A Frequency-Aware Self-Supervised Framework for MEMS-OCT Denoising},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {3},
  pages = {177},
  doi = {10.3390/bios16030177}
}
Kostenlos starten →