EUVIMEDEUVIMED entdecken
Crossref

Toward cell nuclei precision between OCT and H&E images translation using signal-to-noise ratio cycle-consistency

Chih-Hao Liu, Li-Wei Fu, Homer H Chen, Sheng-Lung Huang

Computer Methods and Programs in Biomedicine · 2023

DOI: 10.1016/j.cmpb.2023.107824 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2023. Verfasst von Chih-Hao Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan. Electronic addr…. Hauptthemen laut MEDLINE: Algorithms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Medical image-to-image translation is often difficult and of limited effectiveness due to the differences in image acquisition mechanisms and the diverse structure of biological tissues. This work presents an unpaired image translation model between in-vivo optical coherence tomography (OCT) and ex-vivo Hematoxylin and eosin (H&E) stained images without the need for image stacking, registration, post-processing, and annotation. The model can generate high-quality and highly accurate virtual medical images, and is robust and bidirectional. Our framework introduces random noise to (1) blur redundant features, (2) defend against self-adversarial attacks, (3) stabilize inverse conversion, and (4) mitigate the impact of OCT speckles. We also demonstrate that our model can be pre-trained and then fine-tuned using images from different OCT systems in just a few epochs. Qualitative and quantitative comparisons with traditional image-to-image translation models show the robustness of our proposed signal-to-noise ratio (SNR) cycle-consistency method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsImage Processing, Computer-AssistedSignal-To-Noise RatioTomography, Optical CoherenceCell Nucleus

Stichwörter der Autor:innen

H&EImage translationOCTSpeckle noise

Autor:innen und Institutionen

  • Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan. Electronic address: r10941036@ntu.edu.tw.
  • Graduate Institute of Communication Engineering, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan. Electronic address: r10942078@ntu.edu.tw.
  • Graduate Institute of Communication Engineering, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan; Department of Electrical Engineering, National Taiwan University, No.1, Sec. 4, Roosevelt…
  • Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan; Department of Electrical Engineering, National Taiwan University, No.1, Sec. 4, Roose…

Förderung

  • National Science and Technology Council

Zitieren

APA

Liu, C. H., Fu, L. W., Chen, H. H., & Huang, S. L. (2023). Toward cell nuclei precision between OCT and H&E images translation using signal-to-noise ratio cycle-consistency. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2023.107824

Vancouver

Liu CH, Fu LW, Chen HH, Huang SL. Toward cell nuclei precision between OCT and H&E images translation using signal-to-noise ratio cycle-consistency. Computer Methods and Programs in Biomedicine. 2023. doi:10.1016/j.cmpb.2023.107824

BibTeX
@article{Liu2023,
  author = {Liu, Chih-Hao and Fu, Li-Wei and Chen, Homer H and Huang, Sheng-Lung},
  title = {Toward cell nuclei precision between OCT and H&E images translation using signal-to-noise ratio cycle-consistency},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2023},
  doi = {10.1016/j.cmpb.2023.107824}
}
Kostenlos starten →