Challenges of Wearable Biosensors and Ways to Overcome Them
Biosensors · 13.03.2026 · 16 (3) · 159
DOI: 10.3390/bios16030159 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biosensors, online erschienen am 13.03.2026. Verfasst von Sergei Tarasov und 4 weiteren Autor:innen. Beteiligte Einrichtung: G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Pushchino Center for Biological Research of the Russian Academy of Sciences…. Hauptthemen laut MEDLINE: Biosensing Techniques, Wearable Electronic Devices. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 314 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In the 21st century, there have been radical changes in healthcare related to the transition from a universal approach to personalized medicine based on the unique characteristics of each patient. In large part, this has become possible due to the development and distribution of wearable medical devices that are capable of providing continuous monitoring of a variety of physiological parameters outside medical institutions. The most important of these devices are modern biosensors that allow real-time tracking of various biomarkers in the body, thereby opening up new opportunities for disease prevention, early diagnosis, and personalized treatment strategies. The most obvious example of the transformation is the implementation of wearable devices for continuous glucose monitoring (CGM), which has significantly facilitated the daily lives of millions of people with diabetes. Nevertheless, despite the examples of successful implementation of these devices, their large-scale distribution is associated with many challenges, such as the need for standardization, data transmission security, and the risks of immune responses to implantable devices or infections. This review examines all the current problems of wearable biosensors and possible ways to overcome them. Special emphasis will be placed on devices for continuous glucose monitoring as the most commercially successful representatives of this device class.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- G.K. Skryabin Institute of Biochemistry and Physiology of Microorganisms, Pushchino Center for Biological Research of the Russian Academy of Sciences, 142290 Pushchino, Moscow Region, Russia.
- MLC GT L.L.C-FZ, Meydan Grandstand, 6th floor, Meydan Road, Nad Al Sheba, Dubai, United Arab Emirates.
ORCID-Profile: Sergei Tarasov, Yulia Plekhanova
Zitieren
APA
Tarasov, S., Plekhanova, Y., Reshetilov, A., Melenkov, S., & Saltanov, I. (2026). Challenges of Wearable Biosensors and Ways to Overcome Them. Biosensors, 16(3), 159. https://doi.org/10.3390/bios16030159
Vancouver
Tarasov S, Plekhanova Y, Reshetilov A, Melenkov S, Saltanov I. Challenges of Wearable Biosensors and Ways to Overcome Them. Biosensors. 2026;16(3):159. doi:10.3390/bios16030159
BibTeX
@article{Tarasov2026,
author = {Tarasov, Sergei and Plekhanova, Yulia and Reshetilov, Anatoly and Melenkov, Sergey and Saltanov, Ivan},
title = {Challenges of Wearable Biosensors and Ways to Overcome Them},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {3},
pages = {159},
doi = {10.3390/bios16030159}
}