Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Zhi-Hong Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Pharmacy, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, China. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, Electrochemical Techniques. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Fujian Province Science and Technology Department, State Key Laboratory of Analytical Chemistry for Life Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The ultrasensitive detection of microRNA-17 (miRNA-107) is required for clinical diagnosis. In this work, an aggregation-induced electrochemiluminescence (AIECL) sensor was developed for the quantification of miRNA-107, in which AIECL-active polymer dots (Pdots) were characterized by transmission electron microscopy, ultraviolet–visible spectroscopy, and cyclic voltammetry and used as ECL emitters. Black hole quencher-labeled hairpin DNA (HP-BHQ) was modified on the Pdot surfaces, resulting in the ECL signal of the Pdots being in the “off” state due to the resonant energy transfer (RET) between the BHQ and Pdots. In the presence of miRNA-107, HP-BHQ opened through RNA-DNA hybridization. Subsequently, the introduced duplex-specific nuclease (DSN) facilitated the cleavage of DNA in the RNA–DNA hybrid chain and led to the detachment of HP-BHQ from the electrode surface. The ECL signal of the Pdots recovered, i.e., to the “on” state. The variation in the ECL signal was related to the concentration of the target miRNA-107. As a result, the AIECL biosensor exhibited a wide linear response to miRNA-107 concentrations ranging from 1.0 fM to 10.0 pM, and a low detection limit of 0.82 fM. This work provides a novel platform for the sensitive analysis of miRNA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroRNAsBiosensing TechniquesElectrochemical TechniquesPolymersLuminescent MeasurementsNucleic Acid HybridizationHumansLimit of DetectionElectrodesQuantum Dots

Stichwörter der Autor:innen

aggregation-induced electrochemiluminescenceduplex-specific nucleasemiRNA-107polymer dotsresonance energy transfer

Substanzen

MicroRNAsPolymersMIRN107 microRNA, human

Autor:innen und Institutionen

  • College of Pharmacy, Fujian University of Traditional Chinese Medicine, Fuzhou 350122, China.
  • School of Chemistry and Materials, Yangzhou University, Yangzhou 225002, China.

ORCID-Profile: Hang Gao

Förderung

  • National Natural Science Foundation of China
  • Fujian Province Science and Technology Department
  • State Key Laboratory of Analytical Chemistry for Life Science

Zitieren

APA

Xu, Z. H., Weng, X., Lin, R. M., Tong, H., Guo, Y., Yu, L. S., Gao, H., & Xu, Q. (2026). Highly Sensitive Electrochemiluminescence Analysis of miRNA-107 Using AIE-Active Polymer Dots as Emitters. Biosensors. https://doi.org/10.3390/bios16020099

Vancouver

Xu ZH, Weng X, Lin RM, Tong H, Guo Y, Yu LS, et al. Highly Sensitive Electrochemiluminescence Analysis of miRNA-107 Using AIE-Active Polymer Dots as Emitters. Biosensors. 2026. doi:10.3390/bios16020099

BibTeX
@article{Xu2026,
  author = {Xu, Zhi-Hong and Weng, Xin and Lin, Ruo-Mei and Tong, Hui and Guo, Yang and Yu, Li-Shuang and Gao, Hang and Xu, Qin},
  title = {Highly Sensitive Electrochemiluminescence Analysis of miRNA-107 Using AIE-Active Polymer Dots as Emitters},
  journal = {Biosensors},
  year = {2026},
  doi = {10.3390/bios16020099}
}
Kostenlos starten →