EUVIMEDEUVIMED entdecken
Crossref

Ultrasensitive Electrochemiluminescence Biosensor Based on DNA-Bio-Bar-Code and Hybridization Chain Reaction Dual Signal Amplification for Exosomes Detection

Xiangdan Meng, Xuejiao Pang, Xiangyu Liu, Shuiyou Luo, Xueji Zhang iD, Haifeng Dong iD

Analytical Chemistry · 2024

DOI: 10.1021/acs.analchem.4c02917 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2024. Verfasst von Xiangdan Meng und 5 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Key Laboratory for Bioengineering and Sensing Technology Research Centre for Bioengineering and Sensing Technology School of Chemistry and Bi…. Hauptthemen laut MEDLINE: Biosensing Techniques, Exosomes, Nucleic Acid Hybridization, Electrochemical Techniques. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: the Special Foundation for the State Major Research Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Exosomes have received considerable attention as potent reference markers for the diagnosis of various neoplasms due to their close and direct relationship with the proliferation, adhesion, and migration of tumor. The ultrasensitive detection of cancer-derived low-abundance exosomes is imperative, but still a great challenge. Herein, we report an electrochemiluminescence (ECL) biosensor based on the DNA-bio-bar-code and hybridization chain reaction (HCR)-mediated dual signal amplification for the ultrasensitive detection of cancer-derived exosomes. In this system, two types of aptamers were modified on the magnetic nanoprobe (MNPs) and gold nanoparticles (AuNPs) with numerous bio-bar-code DNA, respectively, which formed "sandwich" structures in the presence of specific target exosomes. The "sandwich" structures were separated under magnetic field, and the numerous bio-bar-code DNA were released by dissolving AuNPs. The released bio-bar-code DNA triggered the HCR procedure to produce a good deal of long DNA duplex structure for embedding in hemin, which generated strong ECL signal in the presence of coreactors for ultrasensitive detection of exosomes. Under the optimal conditions, it exhibited a good linearly of exosomes ranging from 10 to 104 exosomes particle μL-1 with limit of detection down to 5.01 exosome particle μL-1. Furthermore, the high ratio of ECL signal and minor change of ECL intensity indicated the good specificity, stability, and repeatability of this ECL biosensor. Given the good performance for exosome analysis, this ultrasensitive ECL biosensor has a promising application in the clinical diagnosis of early cancers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesExosomesNucleic Acid HybridizationElectrochemical TechniquesGoldLuminescent MeasurementsDNAMetal NanoparticlesHumansLimit of DetectionAptamers, Nucleotide

Substanzen

GoldDNAAptamers, Nucleotide

Autor:innen und Institutionen

  • Beijing Key Laboratory for Bioengineering and Sensing Technology Research Centre for Bioengineering and Sensing Technology School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Be…
  • School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, People's Republic of China.
  • Marshall Laboratory of Biomedical Engineering, Shenzhen Key Laboratory for Nano-Biosensing Technology, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Guangdong 518060, P. R. C…

ORCID-Profile: Xueji Zhang, Haifeng Dong

Förderung

  • the Special Foundation for the State Major Research Program of China

Zitieren

APA

Meng, X., Pang, X., Liu, X., Luo, S., Zhang, X., & Dong, H. (2024). Ultrasensitive Electrochemiluminescence Biosensor Based on DNA-Bio-Bar-Code and Hybridization Chain Reaction Dual Signal Amplification for Exosomes Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c02917

Vancouver

Meng X, Pang X, Liu X, Luo S, Zhang X, Dong H. Ultrasensitive Electrochemiluminescence Biosensor Based on DNA-Bio-Bar-Code and Hybridization Chain Reaction Dual Signal Amplification for Exosomes Detection. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.4c02917

BibTeX
@article{Meng2024,
  author = {Meng, Xiangdan and Pang, Xuejiao and Liu, Xiangyu and Luo, Shuiyou and Zhang, Xueji and Dong, Haifeng},
  title = {Ultrasensitive Electrochemiluminescence Biosensor Based on DNA-Bio-Bar-Code and Hybridization Chain Reaction Dual Signal Amplification for Exosomes Detection},
  journal = {Analytical Chemistry},
  year = {2024},
  doi = {10.1021/acs.analchem.4c02917}
}
Kostenlos starten →