Ultrasensitive Electrochemical Immunoassays of IgG and CA125 Based on Glucose Oxidase-Catalyzed Signal Amplification with Gold Staining
Biosensors · 2025
DOI: 10.3390/bios15100689 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Long Chao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Key Laboratory of Biomedical Nanomaterials and Devices, School of Biological Sicence and Medical Engineering, Hunan University of Technology, Z…. Hauptthemen laut MEDLINE: Glucose Oxidase, Immunoglobulin G, CA-125 Antigen, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: cientific research project of Hunan Provincial Department of Education, Excellent Youth Program of Hunan Provincial Department of Education, Natural Science Foundation of Hunan Province.
Abstract (Originalsprache)
Herein, we propose an ultrasensitive electrochemical immunosensor based on glucose oxidase labeling and enzyme-catalyzed Au staining. In brief, the primary antibody (Ab1), bovine serum albumin, an antigen and then a bionanocomposite that contains a second antibody (Ab2), poly(3-anilineboronic acid) (PABA), Au nanoparticles (AuNPs) and glucose oxidase (GOx) are modified on a glassy carbon electrode coated with multiwalled carbon nanotubes, yielding a corresponding sandwich-type immunoelectrode. In the presence of glucose, a chemical reduction of NaAuCl4 by enzymatically generated H2O2 can precipitate a lot of gold on the Ab2-PABA-AuNPs-GOx immobilized immunoelectrode. In situ anodic stripping voltammetry (ASV) detection of gold in 8 μL 1.0 M aqueous HBr-Br2 is conducted for the antigen assay, and the ASV detection process takes approximately 6 min. This method is employed for the assay of human immunoglobulin G (IgG) and human carbohydrate antigen 125 (CA125), which demonstrates exceptional sensitivity, high selectivity and fewer required reagents/samples. The achieved limits of detection (S/N = 3) by the method are 0.25 fg mL−1 for IgG (approximately equivalent to containing 1 IgG molecule in the 1 microlitre of the analytical solution) and 0.1 nU mL−1 for CA125, which outperforms many previously reported results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, School of Biological Sicence and Medical Engineering, Hunan University of Technology, Zhuzhou 412007, China.
- Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research, Ministry of Education of China, College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha 410081, China.
- College of Design and Engineering, National University of Singapore, 21 Lower Kent Ridge Road, Singapore 119077, Singapore.
ORCID-Profile: Long Chao
Förderung
- cientific research project of Hunan Provincial Department of Education
- Excellent Youth Program of Hunan Provincial Department of Education
- Natural Science Foundation of Hunan Province
- the Scientific Research Project of Hunan Provincial Department of Education
- the Excellent Youth Program of Hunan Provincial Department of Education
- the Natural Science Foundation of Hunan Province
Zitieren
APA
Chao, L., Wu, Z., Qi, S., Xu, A., Huang, Z., & Yan, D. (2025). Ultrasensitive Electrochemical Immunoassays of IgG and CA125 Based on Glucose Oxidase-Catalyzed Signal Amplification with Gold Staining. Biosensors. https://doi.org/10.3390/bios15100689
Vancouver
Chao L, Wu Z, Qi S, Xu A, Huang Z, Yan D. Ultrasensitive Electrochemical Immunoassays of IgG and CA125 Based on Glucose Oxidase-Catalyzed Signal Amplification with Gold Staining. Biosensors. 2025. doi:10.3390/bios15100689
BibTeX
@article{Chao2025,
author = {Chao, Long and Wu, Zhisong and Qi, Shiqiang and Xu, Aigui and Huang, Zhao and Yan, Dexuan},
title = {Ultrasensitive Electrochemical Immunoassays of IgG and CA125 Based on Glucose Oxidase-Catalyzed Signal Amplification with Gold Staining},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15100689}
}