EUVIMEDEUVIMED entdecken
Crossref

Au-decorated NiYFe-LDH/MWCNT nanohybrid-based high-performance immunosensor for ultrasensitive electrochemical detection of cancer antigen 125

Asad M Hadwan, Gholamreza Dehghan, Simin Khataee, Alireza Khataee

Microchimica Acta · 2026

DOI: 10.1007/s00604-026-07833-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Asad M Hadwan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Biochemistry and Molecular Biology, Department of Biology, Faculty of Natural Sciences, University of Tabriz, Tabriz, 51666-16471, Iran. Hauptthemen laut MEDLINE: CA-125 Antigen, Electrochemical Techniques, Nanotubes, Carbon, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 64 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Regarding the importance of early diagnosis of ovarian cancer and its progression monitoring, an ultrasensitive sandwich-type electrochemical immunosensor was developed to detect cancer antigen 125 (CA 125) biomarker. A hybrid nanocomposite was synthesized by integrating COOH-functionalized multi-walled carbon nanotubes (MWCNT-COOH) with a trimetallic NiYFe layered double hydroxide (NiYFe-LDH). To further improve the electrochemical activity, gold nanoparticles (AuNPs) were deposited onto the resulting nanohybrid structure. The final Au@LDH/MWCNT nanocomposite was characterized using standard methods and subsequently employed to modify screen-printed carbon electrodes (SPCEs) for capturing the sandwich structure of the immunosensor. The high specific surface area and biocompatibility of the nanocomposite provided an appropriate microenvironment for the effective capture of primary antibodies (Ab1) and preserving the integrity of the sandwich structure during signal analysis. The output response of the immunosensor was measured utilizing differential pulse voltammetry (DPV), revealing a wide linear range of 0.1 U mL− 1 to 600 U mL− 1 and a low detection limit of 0.0013 U mL− 1. The immunosensor demonstrated excellent selectivity, stability, and reproducibility. Furthermore, its reliable performance for the clinical applications was confirmed by evaluating recoveries using the standard addition and the standard enzyme-linked immunosorbent assay (ELISA) methods. Additionally, the results exhibited that the proposed platform can be further developed for the detection of other cancer-related biomarkers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CA-125 AntigenElectrochemical TechniquesNanotubes, CarbonBiosensing TechniquesGoldHumansImmunoassayMetal NanoparticlesLimit of DetectionAntibodies, ImmobilizedNanocompositesHydroxidesElectrodesOvarian Neoplasms

Stichwörter der Autor:innen

Au@LDH/MWCNT nanocompositeCA 125 biomarkerDifferential pulse voltammetryElectrochemical immunosensorOvarian cancer diagnosisScreen-printed carbon electrode

Substanzen

GoldCA-125 AntigenNanotubes, CarbonAntibodies, ImmobilizedHydroxides

Autor:innen und Institutionen

  • Laboratory of Biochemistry and Molecular Biology, Department of Biology, Faculty of Natural Sciences, University of Tabriz, Tabriz, 51666-16471, Iran.
  • Faculty of Dentistry, Al-Manara University, Maysan Government, 62001, Iraq.
  • Laboratory of Biochemistry and Molecular Biology, Department of Biology, Faculty of Natural Sciences, University of Tabriz, Tabriz, 51666-16471, Iran. gdehghan@tabrizu.ac.ir.
  • Research Center of Biosciences and Biotechnology (RCBB), University of Tabriz, Tabriz, Iran. gdehghan@tabrizu.ac.ir.
  • Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, 51666-16471, Iran.
  • Department of Chemical Engineering, Istanbul Technical University, Istanbul, 34469, Turkey.

Zitieren

APA

Hadwan, A. M., Dehghan, G., Khataee, S., & Khataee, A. (2026). Au-decorated NiYFe-LDH/MWCNT nanohybrid-based high-performance immunosensor for ultrasensitive electrochemical detection of cancer antigen 125. Microchimica Acta. https://doi.org/10.1007/s00604-026-07833-x

Vancouver

Hadwan AM, Dehghan G, Khataee S, Khataee A. Au-decorated NiYFe-LDH/MWCNT nanohybrid-based high-performance immunosensor for ultrasensitive electrochemical detection of cancer antigen 125. Microchimica Acta. 2026. doi:10.1007/s00604-026-07833-x

BibTeX
@article{Hadwan2026,
  author = {Hadwan, Asad M and Dehghan, Gholamreza and Khataee, Simin and Khataee, Alireza},
  title = {Au-decorated NiYFe-LDH/MWCNT nanohybrid-based high-performance immunosensor for ultrasensitive electrochemical detection of cancer antigen 125},
  journal = {Microchimica Acta},
  year = {2026},
  doi = {10.1007/s00604-026-07833-x}
}
Kostenlos starten →