EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

SPR Biosensor Based on Bilayer MoS2 for SARS-CoV-2 Sensing

Talia Tene iD, Stefano Bellucci iD, Cristian Vacacela Gomez iD

Biosensors · 2025

DOI: 10.3390/bios15010021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Talia Tene und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Universidad Técnica Particular de Loja, Loja 110160, Ecuador. Hauptthemen laut MEDLINE: Molybdenum, SARS-CoV-2, Disulfides, Biosensing Techniques. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Técnica Particular de Loja, LNF-INFN: Progetto HPSWFOOD Regione Lazio-CUP I35F20000400005.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The COVID-19 pandemic has highlighted the urgent need for rapid, sensitive, and reliable diagnostic tools for detecting SARS-CoV-2. In this study, we developed and optimized a surface plasmon resonance (SPR) biosensor incorporating advanced materials to enhance its sensitivity and specificity. Key parameters, including the thickness of the silver layer, silicon nitride dielectric layer, molybdenum disulfide (MoS2) layers, and ssDNA recognition layer, were systematically optimized to achieve the best balance between sensitivity, resolution, and attenuation. The optimized configuration, consisting of a 45 nm silver layer, a 13 nm silicon nitride layer, 2 MoS2 layers, and a 5 nm ssDNA layer, demonstrated superior performance for detecting SARS-CoV-2 in PBS solution. The biosensor exhibited high sensitivity at low viral concentrations, achieving a sensitivity of 375.01°/RIU, a detection accuracy of 0.002, and a quality factor of 38.34 at 1.0 mM SARS-CoV-2 concentration. Performance metrics validated the sensor’s capability for reliable detection, particularly in early-stage diagnostics where timely intervention is critical. Moreover, the biosensor’s linear response to refractive index changes confirmed its potential for quantitative viral concentration analysis. This study underlines the significance of integrating advanced materials, such as MoS2 and silicon nitride, to enhance SPR biosensor performance. The findings establish the proposed biosensor as a robust and precise diagnostic tool for SARS-CoV-2 detection, with potential applications in clinical diagnostics and epidemiological monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MolybdenumSARS-CoV-2DisulfidesBiosensing TechniquesCOVID-19Surface Plasmon ResonanceHumansSilicon CompoundsDNA, Single-Stranded

Stichwörter der Autor:innen

MoS2SARS-CoV-2biosensorsilicon nitridesurface plasmon resonance

Substanzen

Molybdenummolybdenum disulfideDisulfidessilicon nitrideSilicon CompoundsDNA, Single-Stranded

Autor:innen und Institutionen

  • Department of Chemistry, Universidad Técnica Particular de Loja, Loja 110160, Ecuador.
  • INFN-Laboratori Nazionali di Frascati, Via E. Fermi 54, 00044 Frascati, Italy.

ORCID-Profile: Talia Tene, Stefano Bellucci, Cristian Vacacela Gomez

Förderung

  • Universidad Técnica Particular de Loja
  • LNF-INFN: Progetto HPSWFOOD Regione Lazio-CUP I35F20000400005

Zitieren

APA

Tene, T., Bellucci, S., & Vacacela Gomez, C. (2025). SPR Biosensor Based on Bilayer MoS2 for SARS-CoV-2 Sensing. Biosensors. https://doi.org/10.3390/bios15010021

Vancouver

Tene T, Bellucci S, Vacacela Gomez C. SPR Biosensor Based on Bilayer MoS2 for SARS-CoV-2 Sensing. Biosensors. 2025. doi:10.3390/bios15010021

BibTeX
@article{Tene2025,
  author = {Tene, Talia and Bellucci, Stefano and Vacacela Gomez, Cristian},
  title = {SPR Biosensor Based on Bilayer MoS2 for SARS-CoV-2 Sensing},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15010021}
}
Kostenlos starten →