A High Sensitive Nanomaterial Coated Side Polished Fiber Sensor for Detection of Cardiac Troponin I Antibody
IEEE Transactions on NanoBioscience · 2025
DOI: 10.1109/tnb.2025.3548823 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on NanoBioscience, 2025. Verfasst von M Valliammai und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Troponin I, Biosensing Techniques, Nanostructures, Fiber Optic Technology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Department of Science and Technology (DST)—Global Innovation and Technology Alliance (GITA), Government of India under the Call for Proposal 2021 India–Taiwan….
Abstract (Originalsprache)
The advent of evanescent field based fiber optic biosensor and advancements in nanotechnology has create an excellent opportunity in label-free detection of biomarkers which plays vital role in the early, rapid and accurate diagnosis of acute diseases. In this work, we demonstrate a high sensitive Molybdenum Tungsten Disulfide (MoWS2) coated side polished fiber (SPF) biosensor for accurate and early diagnosis of cardio vascular disease (CVD). The Cardiac Troponins I (cTnI) is identified as a biomarker of interest for early and rapid diagnosis of CVD. The proposed SPF biosensor exhibits surface plasmonic resonance (SPR) detection due to the evanescent field interaction between MoWS2 nano coated side polished region and anti-CTnI. The proposed SPF biosensor possess the high sensitivity of 82% to detect the cTnI antibody with a limit of detection (LOD) about 17.5 pg/mL. The peak SPR shift have been calculated as 61 nm for analyte concentrations of 500 pg/mL Moreover, the proposed SPF biosensor possess the high degree of selectivity and environmental stability to CTnI among three analytes such as CTnI, Estrogen and Glucose. The hydrophobic interactions of MoWS2 and cTnI antibody leads to chemical free biofunctionalization of antibody in the sensing region. Hence, the simulation results shows the surface interaction strength calculated as 1.29 KJ mol-1/nm2 in order to evaluate the hydrophobic interactions. Thus, the proposed optical biosensor is a promising candidate for "point-of-care" testing of CVD disorders and preclinical assessments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Department of Science and Technology (DST)—Global Innovation and Technology Alliance (GITA), Government of India under the Call for Proposal 2021 India–Taiwan…
Zitieren
APA
Valliammai, M., Mohanraj, J., Esakki, B., Yang, L. J., Wang, C. C., & Bakiya, A. (2025). A High Sensitive Nanomaterial Coated Side Polished Fiber Sensor for Detection of Cardiac Troponin I Antibody. IEEE Transactions on NanoBioscience. https://doi.org/10.1109/tnb.2025.3548823
Vancouver
Valliammai M, Mohanraj J, Esakki B, Yang LJ, Wang CC, Bakiya A. A High Sensitive Nanomaterial Coated Side Polished Fiber Sensor for Detection of Cardiac Troponin I Antibody. IEEE Transactions on NanoBioscience. 2025. doi:10.1109/tnb.2025.3548823
BibTeX
@article{Valliammai2025,
author = {Valliammai, M and Mohanraj, J and Esakki, Balasubramanian and Yang, Lung-Jieh and Wang, Chua-Chin and Bakiya, A},
title = {A High Sensitive Nanomaterial Coated Side Polished Fiber Sensor for Detection of Cardiac Troponin I Antibody},
journal = {IEEE Transactions on NanoBioscience},
year = {2025},
doi = {10.1109/tnb.2025.3548823}
}
EUVIMED