Development of Single-Walled Carbon Nanotube-Based Electrodes with Enhanced Dispersion and Electrochemical Properties for Blood Glucose Monitoring
Biosensors · 19.12.2024 · 14 (12) · 630
DOI: 10.3390/bios14120630 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 19.12.2024. Verfasst von Dong-Sup Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Green Chemical Engineering, Sangmyung University, 31 Sangmyungdae-Gil, Dongnam-Gu, Cheonan 31066, Republic of Korea. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Biosensing Techniques, Electrodes, Blood Glucose. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education.
Abstract (Originalsprache)
The evolution of high-performance electrode materials has significantly impacted the development of real-time monitoring biosensors, emphasizing the need for compatibility with biomaterials and robust electrochemical properties. This work focuses on creating electrode materials utilizing single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs), specifically examining their dispersion behavior and electrochemical characteristics. By using ultrasonic waves, we analyzed the dispersion of CNTs in various solvents, including N, N-dimethylformamide (DMF), deionized water (DW), ethanol, and acetone. The findings revealed that SWCNTs achieved optimal dispersion without precipitation in DMF. Additionally, we observed that the electrical resistance decreased as the concentration of SWCNTs increased from 0.025 to 0.4 g/L, with significant conductivity enhancements noted between 0.2 g/L and 0.4 g/L in DMF. In constructing the biosensor platform, we employed 1-pyrenebutanoic acid succinimidyl ester (PBSE) as a linker molecule, while glucose oxidase (Gox) served as the binding substrate. The interaction between Gox and glucose led to a notable decrease in the biosensor’s resistance values as glucose concentrations ranged from 0.001 to 0.1 M. These results provide foundational insights into the development of SWCNT-based electrode materials and suggest a promising pathway toward the next generation of efficient and reliable biosensors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Green Chemical Engineering, Sangmyung University, 31 Sangmyungdae-Gil, Dongnam-Gu, Cheonan 31066, Republic of Korea.
- Department of Agriculture and Applied Science, Alcorn State University, Lorman, MS 39096, USA.
- Department of Plant and Food Sciences, Sangmyung University, 31 Sangmyungdae-Gil, Dongnam-Gu, Cheonan 31066, Republic of Korea.
- Department of Convergence Bio-Chemical Engineering, Soonchunhyang University, 22, Soonchunhyang-Ro, Sinchang-Myeon, Asan-si 31538, Republic of Korea.
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-Ro, Nowon-Gu, Seoul 01897, Republic of Korea.
- Department of Gyedang College of General Education, Sangmyung University, 31 Sangmyungdae-Gil, Dongnam-Gu, Cheonan 31066, Republic of Korea.
ORCID-Profile: Abdus Sobhan, Jun-Hyun Oh, Jahyun Lee, Chulhwan Park, Jinyoung Lee
Förderung
- Ministry of Education
Zitieren
APA
Kim, D. S., Sobhan, A., Oh, J. H., Lee, J., Park, C., & Lee, J. (2024). Development of Single-Walled Carbon Nanotube-Based Electrodes with Enhanced Dispersion and Electrochemical Properties for Blood Glucose Monitoring. Biosensors, 14(12), 630. https://doi.org/10.3390/bios14120630
Vancouver
Kim DS, Sobhan A, Oh JH, Lee J, Park C, Lee J. Development of Single-Walled Carbon Nanotube-Based Electrodes with Enhanced Dispersion and Electrochemical Properties for Blood Glucose Monitoring. Biosensors. 2024;14(12):630. doi:10.3390/bios14120630
BibTeX
@article{Kim2024,
author = {Kim, Dong-Sup and Sobhan, Abdus and Oh, Jun-Hyun and Lee, Jahyun and Park, Chulhwan and Lee, Jinyoung},
title = {Development of Single-Walled Carbon Nanotube-Based Electrodes with Enhanced Dispersion and Electrochemical Properties for Blood Glucose Monitoring},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {12},
pages = {630},
doi = {10.3390/bios14120630}
}
EUVIMED