Electrochemical and Fluorescence MnO2-Polymer Dot Electrode Sensor for Osteoarthritis-Based Peroxisomal β-Oxidation Knockout Model
Biosensors · 2024
DOI: 10.3390/bios14070357 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Akhmad Irhas Robby und 3 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Industry Institute, Korea National University of Transportation, Chungju 27469, Republic of Korea. Hauptthemen laut MEDLINE: Manganese Compounds, Osteoarthritis, Biosensing Techniques, Polymers. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
A coenzyme A (CoA-SH)-responsive dual electrochemical and fluorescence-based sensor was designed utilizing an MnO2-immobilized-polymer-dot (MnO2@D-PD)-coated electrode for the sensitive detection of osteoarthritis (OA) in a peroxisomal β-oxidation knockout model. The CoA-SH-responsive MnO2@D-PD-coated electrode interacted sensitively with CoA-SH in OA chondrocytes, triggering electroconductivity and fluorescence changes due to cleavage of the MnO2 nanosheet on the electrode. The MnO2@D-PD-coated electrode can detect CoA-SH in immature articular chondrocyte primary cells, as indicated by the significant increase in resistance in the control medium (R24h = 2.17 MΩ). This sensor also sensitively monitored the increase in resistance in chondrocyte cells in the presence of acetyl-CoA inducers, such as phytol (Phy) and sodium acetate (SA), in the medium (R24h = 2.67, 3.08 MΩ, respectively), compared to that in the control medium, demonstrating the detection efficiency of the sensor towards the increase in the CoA-SH concentration. Furthermore, fluorescence recovery was observed owing to MnO2 cleavage, particularly in the Phy- and SA-supplemented media. The transcription levels of OA-related anabolic (Acan) and catabolic factors (Adamts5) in chondrocytes also confirmed the interaction between CoA-SH and the MnO2@D-PD-coated electrode. Additionally, electrode integration with a wireless sensing system provides inline monitoring via a smartphone, which can potentially be used for rapid and sensitive OA diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chemical Industry Institute, Korea National University of Transportation, Chungju 27469, Republic of Korea.
- Department of Chemical & Biological Engineering, Korea National University of Transportation, Chungju 27469, Republic of Korea.
- Integrated Omics Institute, Wonkwang University, Iksan 54538, Republic of Korea.
- Department of Biological Sciences, College of Health Sciences, Wonkwang University, Iksan 54538, Republic of Korea.
ORCID-Profile: Akhmad Irhas Robby, Songling Jiang, Eun-Jung Jin, Sung Young Park
Förderung
- National Research Foundation of Korea
Zitieren
APA
Robby, A. I., Jiang, S., Jin, E. J., & Park, S. Y. (2024). Electrochemical and Fluorescence MnO2-Polymer Dot Electrode Sensor for Osteoarthritis-Based Peroxisomal β-Oxidation Knockout Model. Biosensors. https://doi.org/10.3390/bios14070357
Vancouver
Robby AI, Jiang S, Jin EJ, Park SY. Electrochemical and Fluorescence MnO2-Polymer Dot Electrode Sensor for Osteoarthritis-Based Peroxisomal β-Oxidation Knockout Model. Biosensors. 2024. doi:10.3390/bios14070357
BibTeX
@article{Robby2024,
author = {Robby, Akhmad Irhas and Jiang, Songling and Jin, Eun-Jung and Park, Sung Young},
title = {Electrochemical and Fluorescence MnO2-Polymer Dot Electrode Sensor for Osteoarthritis-Based Peroxisomal β-Oxidation Knockout Model},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14070357}
}
EUVIMED