Integration of Carbon Nanotubes into Manganese Dioxide Nanorods for Enhanced Enzymeless Electrochemical Glucose Sensing with High Sensitivity and Selectivity
Biosensors · 2025
DOI: 10.3390/bios15040215 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Khawtar Hasan Ahmed und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institut National de la Recherche Scientifique (INRS), Énergie Matériaux Télécommunications (EMT), 1650, Boulevard Lionel-Boulet, Varennes, QC J3X 1P…. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Manganese Compounds, Oxides, Biosensing Techniques. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council, Natural Sciences Engineering Research Council of Canada (NSERC), Libyan Ministry of Education.
Abstract (Originalsprache)
Freestanding electrode designs, cost-effective catalysts, and enhanced electrical conductivity are crucial for improving the performance of fourth-generation non-enzymatic glucose electrochemical sensors. These factors enable more efficient, scalable, and durable sensors with better sensitivity, stability, and affordability for real-time glucose monitoring. In this study, we explore a freestanding electrode design combining carbon nanotubes (CNTs) with MnO2 nanorods to enhance charge transfer, increase surface area, and optimize catalytic activity. This CNTs/MnO2 electrode demonstrates exceptional catalytic activity for glucose oxidation, achieving a high sensitivity of 309.73 µA cm−2 mM−1 within a linear range of 0.5 to 10 mM—well above typical physiological glucose levels (3–8 mM), with a detection limit of 0.19 mM at a signal-to-noise ratio of 3. The electrode also shows excellent durability and remarkable selectivity for glucose over common interferents like ascorbic acid and uric acid, as well as antifouling properties in the presence of KCl. These attributes are essential for accurate glucose detection in complex biological samples. The integration of MnO2 nanorods with CNTs in freestanding nanostructures opens up exciting opportunities for developing high-performance, robust electrochemical sensors for diverse applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institut National de la Recherche Scientifique (INRS), Énergie Matériaux Télécommunications (EMT), 1650, Boulevard Lionel-Boulet, Varennes, QC J3X 1P7, Canada.
ORCID-Profile: Alonso Moreno Zuria, Mohamed Mohamedi
Förderung
- Natural Sciences and Engineering Research Council
- Natural Sciences Engineering Research Council of Canada (NSERC)
- Libyan Ministry of Education
Zitieren
APA
Ahmed, K. H., Zuria, A. M., & Mohamedi, M. (2025). Integration of Carbon Nanotubes into Manganese Dioxide Nanorods for Enhanced Enzymeless Electrochemical Glucose Sensing with High Sensitivity and Selectivity. Biosensors. https://doi.org/10.3390/bios15040215
Vancouver
Ahmed KH, Zuria AM, Mohamedi M. Integration of Carbon Nanotubes into Manganese Dioxide Nanorods for Enhanced Enzymeless Electrochemical Glucose Sensing with High Sensitivity and Selectivity. Biosensors. 2025. doi:10.3390/bios15040215
BibTeX
@article{Ahmed2025,
author = {Ahmed, Khawtar Hasan and Zuria, Alonso Moreno and Mohamedi, Mohamed},
title = {Integration of Carbon Nanotubes into Manganese Dioxide Nanorods for Enhanced Enzymeless Electrochemical Glucose Sensing with High Sensitivity and Selectivity},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15040215}
}
EUVIMED