Fachartikel in der Zeitschrift Biosensors, online erschienen am 07.06.2024. Verfasst von Anastasia Skonta und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Biotechnology, Department of Biological Applications and Technologies, University of Ioannina, 45110 Ioannina, Greece. Hauptthemen laut MEDLINE: Biosensing Techniques, Chitosan, Smartphone, Colorimetry. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Nowadays, biosensors are gaining increasing interest in foods’ and beverages’ quality control, owing to their economic production, enhanced sensitivity, specificity, and faster analysis. In particular, colorimetric biosensors can be combined with color recognition applications on smartphones for the detection of analytes, rendering the whole procedure more applicable in everyday life. Herein, chitosan (CS) films were prepared with the deep eutectic solvent (DES) choline chloride/urea/glycerol (ChCl:U:Gly). Glucose oxidase (GOx), a widely utilized enzyme in quality control, was immobilized within CS films through glutaraldehyde (GA), leading to the formation of CS/GOx films. The optimized GOx concentration and DES content were determined for the films. Moreover, the effect of the pH and temperature of the glucose oxidation reaction on the enzymatic activity of GOx was studied. The structure, stability, and specificity of the CS/GOx films as well as the Km values of free and immobilized GOx were also determined. Finally, the analytical performance of the films was studied by using both a spectrophotometer and a color recognition application on a smartphone. The results demonstrated that the films were highly accurate, specific to glucose, and stable when stored at 4 °C for 4 weeks and when reused 10 times, without evident activity loss. Furthermore, the films displayed a good linear response range (0.1–0.8 mM) and a good limit of detection (LOD, 33 μM), thus being appropriate for the estimation of glucose concentration in real samples through a smartphone application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Biotechnology, Department of Biological Applications and Technologies, University of Ioannina, 45110 Ioannina, Greece.
- Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece.
ORCID-Profile: Myrto G Bellou, Theodore E Matikas, Haralambos Stamatis
Zitieren
APA
Skonta, A., Bellou, M. G., Matikas, T. E., & Stamatis, H. (2024). Colorimetric Glucose Biosensor Based on Chitosan Films and Its Application for Glucose Detection in Beverages Using a Smartphone Application. Biosensors, 14(6), 299. https://doi.org/10.3390/bios14060299
Vancouver
Skonta A, Bellou MG, Matikas TE, Stamatis H. Colorimetric Glucose Biosensor Based on Chitosan Films and Its Application for Glucose Detection in Beverages Using a Smartphone Application. Biosensors. 2024;14(6):299. doi:10.3390/bios14060299
BibTeX
@article{Skonta2024,
author = {Skonta, Anastasia and Bellou, Myrto G and Matikas, Theodore E and Stamatis, Haralambos},
title = {Colorimetric Glucose Biosensor Based on Chitosan Films and Its Application for Glucose Detection in Beverages Using a Smartphone Application},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {6},
pages = {299},
doi = {10.3390/bios14060299}
}
EUVIMED