Smartphone and paper-based device for glucose monitoring using acetylene black-hemin nanozyme as catalyst

Xiaojuan Yi, Yonghua Yuan, Min Qing, Lulu Wang, Huizhen Li, Lijuan Bai

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2023

DOI: 10.1016/j.saa.2023.122667 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2023. Verfasst von Xiaojuan Yi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing 400016, PR China. Hauptthemen laut MEDLINE: Diabetes Mellitus, Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glucose management is an important part of disease control for diabetes patients, thus the development of a rapid and real-time point of care testing (POCT) device for monitoring blood glucose is of great significance. In this work, a paper-based analytical device (PAD) is constructed by combining acetylene black (AB)-hemin complex modified filter paper as sensing platform with a smartphone as signal detector. Large specific surface area of AB decreases the self-associate and aggregate of hemin in aqueous solution, resulting in improved peroxidase-like activity of hemin. Compared with graphene oxide supported hemin, AB-hemin exhibits superior signal response on paper. Glucose oxidase (GOx) catalyzes the conversion of blood glucose to hydrogen peroxide, and then AB-hemin complex catalyzes the oxidation of colorless 3,3',5,5'-tetramethylbenzidine (TMB) to blue TMB oxidized products (TMB+) in the presence of hydrogen peroxide, thus achieving the visual detection of blood glucose. In optimal conditions, PAD provides an applicable linear range from 0.2 mM to 30 mM and a low limit of detection (LOD) (0.06 mM). Notably, the detection accuracy of the developed paper-based sensor is in good agreement with that of the commercially available blood glucose meter (p > 0.05). Moreover, the proposed PAD presents high recoveries from 95.4% to 112% (RSD ≤ 3.2%), and therefore holds great potential for glucose monitoring and diabetes diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetes MellitusBiosensing TechniquesHumansBlood GlucoseHeminSmartphoneBlood Glucose Self-MonitoringHydrogen PeroxideGlucoseAlkynesColorimetryLimit of DetectionGlucose Oxidase

Stichwörter der Autor:innen

Acetylene blackBlood glucoseHeminNanozymePaper-based analytical device

Substanzen

Blood GlucoseHeminHydrogen PeroxideGlucoseAlkynesGlucose Oxidase

Autor:innen und Institutionen

  • Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing 400016, PR China.
  • Research Center for Pharmacodynamic Evaluation Engineering Technology of Chongqing, College of Pharmacy, Chongqing Medical University, Chongqing 400016, PR China.
  • Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing 400016, PR China. Electronic address: bailj1018@cqmu.edu.cn.

Zitieren

APA

Yi, X., Yuan, Y., Qing, M., Wang, L., Li, H., & Bai, L. (2023). Smartphone and paper-based device for glucose monitoring using acetylene black-hemin nanozyme as catalyst. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2023.122667

Vancouver

Yi X, Yuan Y, Qing M, Wang L, Li H, Bai L. Smartphone and paper-based device for glucose monitoring using acetylene black-hemin nanozyme as catalyst. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2023. doi:10.1016/j.saa.2023.122667

BibTeX
@article{Yi2023,
  author = {Yi, Xiaojuan and Yuan, Yonghua and Qing, Min and Wang, Lulu and Li, Huizhen and Bai, Lijuan},
  title = {Smartphone and paper-based device for glucose monitoring using acetylene black-hemin nanozyme as catalyst},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2023},
  doi = {10.1016/j.saa.2023.122667}
}
Kostenlos starten →