Rapid Microfluidic Immuno-Biosensor Detection System for the Point-of-Care Determination of High-Sensitivity Urinary C-Reactive Protein
Biosensors · 2024
DOI: 10.3390/bios14060283 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Szu-Jui Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan. Hauptthemen laut MEDLINE: C-Reactive Protein, Biosensing Techniques, Point-of-Care Systems, Enzyme-Linked Immunosorbent Assay. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council.
Abstract (Originalsprache)
A microfluidic immuno-biosensor detection system consisting of a microfluidic spectrum chip and a micro-spectrometer detection device is presented for the rapid point-of-care (POC) detection and quantification of high-sensitivity C-reactive protein (hs-CRP) in urine. The detection process utilizes a highly specific enzyme-linked immunosorbent assay (ELISA) method, in which capture antibodies and detection antibodies are pre-deposited on the substrate of the microchip and used to form an immune complex with the target antigen. Horseradish peroxidase (HRP) is added as a marker enzyme, followed by a colorimetric reaction using 3,3′,5,5′-tetramethylbenzidine (TMB). The absorbance values (a.u.) of the colorimetric reaction compounds are measured using a micro-spectrometer device and used to measure the corresponding hs-CRP concentration according to the pre-established calibration curve. It is shown that the hs-CRP concentration can be determined within 50 min. In addition, the system achieves recovery rates of 93.8–106.2% in blind water samples and 94.5–104.6% in artificial urine. The results showed that the CRP detection results of 41 urine samples from patients with chronic kidney disease (CKD) were highly consistent with the conventional homogeneous particle-enhanced turbidimetric immunoassay (PETIA) method’s detection results (R2 = 0.9910). The experimental results showed its applicability in the detection of CRP in both urine and serum. Overall, the results indicate that the current microfluidic ELISA detection system provides an accurate and reliable method for monitoring the hs-CRP concentration in point-of-care applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan.
- Division of Nephrology, Department of Internal Medicine, National Cheng Kung University Hospital, Tainan 70101, Taiwan.
- College of Medicine, National Cheng Kung University, Tainan 70101, Taiwan.
ORCID-Profile: Szu-Jui Chen, Song-Yu Lu, Chin-Chung Tseng, Kuan-Hsun Huang, To-Lin Chen, Lung-Ming Fu
Förderung
- National Science and Technology Council
Zitieren
APA
Chen, S. J., Lu, S. Y., Tseng, C. C., Huang, K. H., Chen, T. L., & Fu, L. M. (2024). Rapid Microfluidic Immuno-Biosensor Detection System for the Point-of-Care Determination of High-Sensitivity Urinary C-Reactive Protein. Biosensors. https://doi.org/10.3390/bios14060283
Vancouver
Chen SJ, Lu SY, Tseng CC, Huang KH, Chen TL, Fu LM. Rapid Microfluidic Immuno-Biosensor Detection System for the Point-of-Care Determination of High-Sensitivity Urinary C-Reactive Protein. Biosensors. 2024. doi:10.3390/bios14060283
BibTeX
@article{Chen2024,
author = {Chen, Szu-Jui and Lu, Song-Yu and Tseng, Chin-Chung and Huang, Kuan-Hsun and Chen, To-Lin and Fu, Lung-Ming},
title = {Rapid Microfluidic Immuno-Biosensor Detection System for the Point-of-Care Determination of High-Sensitivity Urinary C-Reactive Protein},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14060283}
}