EUVIMEDEUVIMED entdecken
Crossref

A portable all-in-one microfluidic device with real-time colorimetric LAMP for HPV16 and HPV18 DNA point-of-care testing

Hao Bai, Yuqing Liu, Linbo Gao, Tao Wang, Xiaoli Zhang, Jie Hu, Lisha Ding, Yueting Zhang, Qian Wang, Lei Wang, Jianlong Li, Zhifeng Zhang und 5 weitere

Biosensors and Bioelectronics · 2024-03 · 248 · 115968

DOI: 10.1016/j.bios.2023.115968 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-03. Verfasst von Hao Bai und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, China; Med+X Center for Manufacturing, West China Hospit…. Hauptthemen laut MEDLINE: Papillomavirus Infections, Biosensing Techniques. Die Arbeit wurde bisher 51-mal zitiert (Crossref) und nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Screening for high-risk human papillomavirus (HPV) infection is one of the most important preventative measures for cervical cancer. However, fast, convenient, and low-cost HPV detection remains challenging, especially in resource-limited settings. Here, we report a portable all-in-one device (PAD) for point-of-care testing (POCT) for HPV16 and HPV18 DNA in cervical swabs. The PAD was engineered to integrate modules for extraction-free sample lysis, loop-mediated isothermal amplification (LAMP) with lyophilized reagent beads, and real-time colorimetric signal sensing into a single miniaturized device, considerably shortening the sample-to-result time to 15 min. The precision liquid handling in the completely sealed microfluidic chip is achieved by a uniquely designed pressure-balanced automatic liquid flow mechanism, thereby eliminating the need for manual manipulation of liquids and thus the risk of biohazards. The PAD employs an improved real-time colorimetric LAMP (rcLAMP) assay with a limit of detection (LOD) of 1 copy/μL, enabled by enhanced assay chemistry to maximize the reaction kinetics. To validate this device for clinical application, we tested 206 clinical cervical swab samples and obtained a sensitivity of 92.1% and a specificity of 99.0%. This custom PAD enabled by microfluidic and electronic engineering techniques can be configured for the simultaneous detection of HPV16 and HPV18 or other pathogens in point-of-care applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Papillomavirus InfectionsBiosensing TechniquesFemaleHumansMicrofluidicsHuman papillomavirus 16Human papillomavirus 18ColorimetryNucleic Acid Amplification TechniquesPoint-of-Care TestingDNA, ViralLab-On-A-Chip DevicesSensitivity and Specificity

Stichwörter der Autor:innen

Diagnostic deviceHuman papillomavirusMicrofluidicsPoint-of-care testingReal-time colorimetric LAMP

Substanzen

DNA, Viral

Autor:innen und Institutionen

  • Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, 610041, China; Med+X Center for Manufacturing, West China Hospital, Sichuan University, Chengdu, 610041, China.
  • Department of Obstetrics and Gynecology, West China Second University Hospital, Sichuan University, Chengdu, 610041, China; Center for Translational Medicine, Key Laboratory of Birth Defects and Related Diseases of Wome…
  • Center for Translational Medicine, Key Laboratory of Birth Defects and Related Diseases of Women and Children, West China Second University Hospital, Sichuan University, Chengdu, 610041, China.
  • Med+X Center for Manufacturing, West China Hospital, Sichuan University, Chengdu, 610041, China; Precision Medicine Center, West China Hospital, Sichuan University, Chengdu, 610041, China.
  • One-Chip Biotechnology Co. Ltd, Chengdu, 610041, China.
  • Beijing Advanced Innovation Center for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology, School of Engineering Medicine, Beihang University, Beijing, 100083, China.

Zitieren

APA

Bai, H., Liu, Y., Gao, L., Wang, T., Zhang, X., Hu, J., Ding, L., Zhang, Y., Wang, Q., Wang, L., Li, J., Zhang, Z., Wang, Y., Shen, C., Ying, B., Niu, X., & Hu, W. (2024). A portable all-in-one microfluidic device with real-time colorimetric LAMP for HPV16 and HPV18 DNA point-of-care testing. Biosensors and Bioelectronics, 248, 115968. https://doi.org/10.1016/j.bios.2023.115968

Vancouver

Bai H, Liu Y, Gao L, Wang T, Zhang X, Hu J, et al. A portable all-in-one microfluidic device with real-time colorimetric LAMP for HPV16 and HPV18 DNA point-of-care testing. Biosensors and Bioelectronics. 2024;248:115968. doi:10.1016/j.bios.2023.115968

BibTeX
@article{Bai2024,
  author = {Bai, Hao and Liu, Yuqing and Gao, Linbo and Wang, Tao and Zhang, Xiaoli and Hu, Jie and Ding, Lisha and Zhang, Yueting and Wang, Qian and Wang, Lei and Li, Jianlong and Zhang, Zhifeng and Wang, Yang and Shen, Chenlan and Ying, Binwu and Niu, Xiaoyu and Hu, Wenchuang},
  title = {A portable all-in-one microfluidic device with real-time colorimetric LAMP for HPV16 and HPV18 DNA point-of-care testing},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {248},
  pages = {115968},
  doi = {10.1016/j.bios.2023.115968}
}
Kostenlos starten →