Highly Sensitive and Linear Resonator-Based Biosensor for White Blood Cell Counting: Feasible Measurement Method and Intrinsic Mechanism Exploration
Biosensors · 07.04.2024 · 14 (4) · 180
DOI: 10.3390/bios14040180 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 07.04.2024. Verfasst von Yi-Ke Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Internet of Things Engineering, Institute of Advanced Technology, Jiangnan University, Wuxi 214122, China. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, Postgraduate Research & Practice Innovation Program of Jiangsu Province.
Abstract (Originalsprache)
Since different quantities of white blood cells (WBCs) in solution possess an adaptive osmotic pressure of cells, the WBCs themselves and in solution have similar concentrations, resulting in them having similar dielectric properties. Therefore, a microwave sensor could have difficulty in sensing the quantity variation when WBCs are in solution. This paper presents a highly sensitive, linear permittivity-inspired microwave biosensor for WBCs, counting through the evaporation method. Such a measurement method is proposed to record measurements after the cell solution is dripped onto the chip and is completely evaporated naturally. The proposed biosensor consists of an air-bridged asymmetric differential inductor and a centrally located circular fork-finger capacitor fabricated on a GaAs substrate using integrated passive fabrication technology. It is optimized to feature a larger sensitive area and improved Q-factor, which increases the effective area of interaction between cells and the electromagnetic field and facilitates the detection of their changes in number. The sensing relies on the dielectric properties of the cells and the change in the dielectric constant for different concentrations, and the change in resonance properties, which mainly represents the frequency shift, corresponds to the macroscopic change in the concentration of the cells. The microwave biosensors are used to measure biological samples with concentrations ranging from 0.25 × 106 to 8 × 106 cells per mL in a temperature (26.00 ± 0.40 °C) and humidity (54.40 ± 3.90 RH%) environment. The measurement results show a high sensitivity of 25.06 Hz/cells·mL−1 with a highly linear response of r2 = 0.99748. In addition, a mathematical modeling of individual cells in suspension is performed to estimate the dielectric constant of individual cells and further explain the working mechanism of the proposed microwave biosensor.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Internet of Things Engineering, Institute of Advanced Technology, Jiangnan University, Wuxi 214122, China.
- State Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
- Key Laboratory of Biopharmaceutical Preparation and Delivery, Chinese Academy of Sciences, Beijing 100190, China.
- School of Biotechnology, The Key Laboratory of Carbohydrate Chemistry and Biotechnology, Ministry of Education, Jiangnan University, Wuxi 214122, China.
ORCID-Profile: Yan-Feng Jiang, Xiao-Dong Gao, Tian Qiang
Förderung
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
- Postgraduate Research & Practice Innovation Program of Jiangsu Province
- Open Project of the Key Laboratory of Nanodevices and Applications, Chinese Academy of Sciences
- Postgraduate Research & Practice Innovation Program of Jiangsu Province
Zitieren
APA
Wang, Y. K., Shi, B. W., Zhao, J. M., Wang, Y. X., Jiang, Y. F., Yang, G. L., Gao, X. D., & Qiang, T. (2024). Highly Sensitive and Linear Resonator-Based Biosensor for White Blood Cell Counting: Feasible Measurement Method and Intrinsic Mechanism Exploration. Biosensors, 14(4), 180. https://doi.org/10.3390/bios14040180
Vancouver
Wang YK, Shi BW, Zhao JM, Wang YX, Jiang YF, Yang GL, et al. Highly Sensitive and Linear Resonator-Based Biosensor for White Blood Cell Counting: Feasible Measurement Method and Intrinsic Mechanism Exploration. Biosensors. 2024;14(4):180. doi:10.3390/bios14040180
BibTeX
@article{Wang2024,
author = {Wang, Yi-Ke and Shi, Bo-Wen and Zhao, Jun-Ming and Wang, Yan-Xiong and Jiang, Yan-Feng and Yang, Gang-Long and Gao, Xiao-Dong and Qiang, Tian},
title = {Highly Sensitive and Linear Resonator-Based Biosensor for White Blood Cell Counting: Feasible Measurement Method and Intrinsic Mechanism Exploration},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {4},
pages = {180},
doi = {10.3390/bios14040180}
}