Customizable Nichrome Wire Heaters for Molecular Diagnostic Applications
Biosensors · 2024
DOI: 10.3390/bios14030152 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Juhee Lim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea. Hauptthemen laut MEDLINE: Escherichia coli O157, Nucleic Acids, Chromium Alloys. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Korea Institute for Advancement of Technology.
Abstract (Originalsprache)
Accurate sample heating is vital for nucleic acid extraction and amplification, requiring a sophisticated thermal cycling process in nucleic acid detection. Traditional molecular detection systems with heating capability are bulky, expensive, and primarily designed for lab settings. Consequently, their use is limited where lab systems are unavailable. This study introduces a technique for performing the heating process required in molecular diagnostics applicable for point-of-care testing (POCT), by presenting a method for crafting customized heaters using freely patterned nichrome (NiCr) wire. This technique, fabricating heaters by arranging protrusions on a carbon black-polydimethylsiloxane (PDMS) cast and patterning NiCr wire, utilizes cost-effective materials and is not constrained by shape, thereby enabling customized fabrication in both two-dimensional (2D) and three-dimensional (3D). To illustrate its versatility and practicality, a 2D heater with three temperature zones was developed for a portable device capable of automatic thermocycling for polymerase chain reaction (PCR) to detect Escherichia coli (E. coli) O157:H7 pathogen DNA. Furthermore, the detection of the same pathogen was demonstrated using a customized 3D heater surrounding a microtube for loop-mediated isothermal amplification (LAMP). Successful DNA amplification using the proposed heater suggests that the heating technique introduced in this study can be effectively applied to POCT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea.
- School of Electrical Engineering, Pukyong National University, Busan 48513, Republic of Korea.
- Major of Biomedical Engineering, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan 48513, Republic of Korea.
ORCID-Profile: Yong Wook Lee, Joong Ho Shin
Förderung
- National Research Foundation of Korea
- Korea Institute for Advancement of Technology
Zitieren
APA
Lim, J., Han, W., Thang, L. T. H., Lee, Y. W., & Shin, J. H. (2024). Customizable Nichrome Wire Heaters for Molecular Diagnostic Applications. Biosensors. https://doi.org/10.3390/bios14030152
Vancouver
Lim J, Han W, Thang LTH, Lee YW, Shin JH. Customizable Nichrome Wire Heaters for Molecular Diagnostic Applications. Biosensors. 2024. doi:10.3390/bios14030152
BibTeX
@article{Lim2024,
author = {Lim, Juhee and Han, Won and Thang, Le Tran Huy and Lee, Yong Wook and Shin, Joong Ho},
title = {Customizable Nichrome Wire Heaters for Molecular Diagnostic Applications},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14030152}
}
EUVIMED