Detection of Reverse Transcriptase LAMP-Amplified Nucleic Acid from Oropharyngeal Viral Swab Samples Using Biotinylated DNA Probes through a Lateral Flow Assay
Biosensors · 2023
DOI: 10.3390/bios13110988 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Saloni Agarwal und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Biochemistry and Biology, Chair of Molecular Bioanalysis and Bioelectronics, University of Potsdam, Karl-Liebknecht-Strasse 24/25, 1447…. Hauptthemen laut MEDLINE: COVID-19, Nucleic Acids. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union's Horizon 2020 Research and Innovation Program, Federal Ministry of Education and Research, Federal Ministry of Education and Research, Germany.
Abstract (Originalsprache)
This study focuses on three key aspects: (a) crude throat swab samples in a viral transport medium (VTM) as templates for RT-LAMP reactions; (b) a biotinylated DNA probe with enhanced specificity for LFA readouts; and (c) a digital semi-quantification of LFA readouts. Throat swab samples from SARS-CoV-2 positive and negative patients were used in their crude (no cleaning or pre-treatment) forms for the RT-LAMP reaction. The samples were heat-inactivated but not treated for any kind of nucleic acid extraction or purification. The RT-LAMP (20 min processing time) product was read out by an LFA approach using two labels: FITC and biotin. FITC was enzymatically incorporated into the RT-LAMP amplicon with the LF-LAMP primer, and biotin was introduced using biotinylated DNA probes, specifically for the amplicon region after RT-LAMP amplification. This assay setup with biotinylated DNA probe-based LFA readouts of the RT-LAMP amplicon was 98.11% sensitive and 96.15% specific. The LFA result was further analysed by a smartphone-based IVD device, wherein the T-line intensity was recorded. The LFA T-line intensity was then correlated with the qRT-PCR Ct value of the positive swab samples. A digital semi-quantification of RT-LAMP-LFA was reported with a correlation coefficient of R2 = 0.702. The overall RT-LAMP-LFA assay time was recorded to be 35 min with a LoD of three RNA copies/µL (Ct-33). With these three advancements, the nucleic acid testing-point of care technique (NAT-POCT) is exemplified as a versatile biosensor platform with great potential and applicability for the detection of pathogens without the need for sample storage, transportation, or pre-processing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute for Biochemistry and Biology, Chair of Molecular Bioanalysis and Bioelectronics, University of Potsdam, Karl-Liebknecht-Strasse 24/25, 14476 Potsdam, Germany.
- Institute for Molecular Diagnostics and Bioanalysis-IMDB gGmbH, Am Mühlenberg 10, 14476 Potsdam, Germany.
ORCID-Profile: Saloni Agarwal, Mojdeh Hamidizadeh, Frank F Bier
Förderung
- European Union's Horizon 2020 Research and Innovation Program
- Federal Ministry of Education and Research
- Federal Ministry of Education and Research, Germany
- European Union’s Horizon 2020 research and innovation programme
- German Research Foundation (DFG)
Zitieren
APA
Agarwal, S., Hamidizadeh, M., & Bier, F. F. (2023). Detection of Reverse Transcriptase LAMP-Amplified Nucleic Acid from Oropharyngeal Viral Swab Samples Using Biotinylated DNA Probes through a Lateral Flow Assay. Biosensors. https://doi.org/10.3390/bios13110988
Vancouver
Agarwal S, Hamidizadeh M, Bier FF. Detection of Reverse Transcriptase LAMP-Amplified Nucleic Acid from Oropharyngeal Viral Swab Samples Using Biotinylated DNA Probes through a Lateral Flow Assay. Biosensors. 2023. doi:10.3390/bios13110988
BibTeX
@article{Agarwal2023,
author = {Agarwal, Saloni and Hamidizadeh, Mojdeh and Bier, Frank F},
title = {Detection of Reverse Transcriptase LAMP-Amplified Nucleic Acid from Oropharyngeal Viral Swab Samples Using Biotinylated DNA Probes through a Lateral Flow Assay},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13110988}
}
EUVIMED