MoS2/S@g-CN Composite Electrode for L-Tryptophan Sensing
Biosensors · 2023
DOI: 10.3390/bios13110967 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Theophile Niyitanga und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea. Hauptthemen laut MEDLINE: Graphite. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Saud University, Riyadh, Saudi Arabia.
Abstract (Originalsprache)
L-tryptophan (L-TRP) is an essential amino acid responsible for the establishment and maintenance of a positive nitrogen equilibrium in the nutrition of human beings. Therefore, it is vital to quantify the amount of L-tryptophan in our body. Herein, we report the MoS2/S@g-CN-modified glassy carbon electrode for the electrochemical detection of L-tryptophan (L-TRP). The MoS2/S@g-CN composite was successfully synthesized using an efficient and cost-effective hydrothermal method. The physical and chemical properties of the synthesized composite were analyzed using powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and energy-dispersive X-ray analysis (EDX). The crystallite size of the composite was calculated as 39.4 nm, with porous balls of MoS2 decorated over the S@g-CN surface. The XPS spectrum confirmed the presence of Mo, S, O, C, and N elements in the sample. The synthesized nanocomposite was further used to modify the glassy carbon (GC) electrode (MoS2/S@g-CN/GC). This MoS2/S@g-CN/GC was used for the electrochemical detection of L-TRP using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. For the purpose of comparison, the effects of the scanning rate and the concentration of L-TRP on the current response for the bare GC, S@g-CN/GC, MoS2/GC, and MoS2/S@g-CN/GC were studied in detail. The MoS2/S@g-CN-modified GC electrode exhibited a rational limit of detection (LoD) of 0.03 µM and a sensitivity of 1.74 µA/ µMcm2, with excellent stability, efficient repeatability, and high selectivity for L-TRP detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Materials Science and Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea.
- Department of Chemistry, Medi-Caps University, Indore 453331, Madhya Pradesh, India.
- Research and Development Cell, Indian Institute of Technology, Indore 453552, Madhya Pradesh, India.
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia.
ORCID-Profile: Archana Chaudhary, Rais Ahmad Khan, Haekyoung Kim
Förderung
- King Saud University, Riyadh, Saudi Arabia
Zitieren
APA
Niyitanga, T., Pathak, A., Chaudhary, A., Khan, R. A., & Kim, H. (2023). MoS2/S@g-CN Composite Electrode for L-Tryptophan Sensing. Biosensors. https://doi.org/10.3390/bios13110967
Vancouver
Niyitanga T, Pathak A, Chaudhary A, Khan RA, Kim H. MoS2/S@g-CN Composite Electrode for L-Tryptophan Sensing. Biosensors. 2023. doi:10.3390/bios13110967
BibTeX
@article{Niyitanga2023,
author = {Niyitanga, Theophile and Pathak, Aarti and Chaudhary, Archana and Khan, Rais Ahmad and Kim, Haekyoung},
title = {MoS2/S@g-CN Composite Electrode for L-Tryptophan Sensing},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13110967}
}
EUVIMED