EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Polypyrrole/carbon dot nanocomposite as an electrochemical biosensor for liquid biopsy analysis of tryptophan in the human serum of normal and breast cancer women

Fatma A M Abdel-Aal, Rania M Kamel, Asmaa A Abdeltawab, Fardous A Mohamed, Abdel-Maaboud I Mohamed

Analytical and Bioanalytical Chemistry · 2023-08 · 415 (20) · 4985-5001

DOI: 10.1007/s00216-023-04784-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 04.07.2023. Verfasst von Fatma A M Abdel-Aal und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Assiut University, Assiut, 71526, Egypt. fatmamoustafa@aun.edu.eg. Hauptthemen laut MEDLINE: Graphite, Breast Neoplasms, Biosensing Techniques, Nanocomposites. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Assiut University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Liquid biopsy analysis represents a suitable alternative analysis procedure in several cases where no tumor tissue is available or in poor patient conditions. Amino acids can play a crucial role in aiding cancer diagnosis. Monitoring of tryptophan (Trp) catabolism can aid in tracking cancer progression. Therefore, a novel nanocomposite was fabricated using overoxidized polypyrrole film doped with nano-carbon dots (nano-CDs) on the pencil graphite electrode (PGE) surface for sensitive evaluation of Trp in human serum. Using square wave voltammetry (SWV), the overoxidized polypyrrole/carbon dots/pencil graphite electrode (Ov-Ox PPy/CDs/PGE) achieved excellent electrochemical catalytic activity for evaluating Trp. The modified electrode, known as Ov-Ox PPy/CDs/PGE, demonstrated superior electrochemical catalytic activity compared to bare PGE, CDs/PGE, PPy/PGE, and PPy/CDs/PGE for evaluation of Trp. The method’s excellent sensitivity was confirmed by the low limits of detection (LOD = 0.003 μmol L −1 ) and limit of quantitation (LOQ = 0.009 μmol L − 1 ). The biosensor that was developed can measure tryptophan (Trp) levels in the serum of both healthy individuals and female breast cancer patients with high accuracy and sensitivity. The results indicate that there is a significant difference, as shown by the F -test, between healthy individuals and those with breast cancer. This suggests that Trp amino acid could be an essential biomarker for cancer diagnosis. Consequently, liquid biopsy analysis presents a valuable opportunity for early disease detection, particularly for cancer. Graphical abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteBreast NeoplasmsBiosensing TechniquesNanocompositesHumansFemaleCarbonPolymersTryptophanPyrrolesElectrochemical TechniquesElectrodes

Stichwörter der Autor:innen

BiomarkersCarbon dotsHuman serumPolypyrroleSquare wave voltammetryTryptophan

Substanzen

CarbonpolypyrrolePolymersGraphiteTryptophanPyrroles

Autor:innen und Institutionen

  • Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Assiut University, Assiut, 71526, Egypt. fatmamoustafa@aun.edu.eg.
  • Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Assiut University, Assiut, 71526, Egypt.
  • Clinical Oncology and Nuclear Medicine Department, Faculty of Medicine, Assuit University, Assiut, 71526, Egypt.

Förderung

  • Assiut University

Zitieren

APA

Abdel-Aal, F. A. M., Kamel, R. M., Abdeltawab, A. A., Mohamed, F. A., & Mohamed, A. I. (2023). Polypyrrole/carbon dot nanocomposite as an electrochemical biosensor for liquid biopsy analysis of tryptophan in the human serum of normal and breast cancer women. Analytical and Bioanalytical Chemistry, 415(20), 4985-5001. https://doi.org/10.1007/s00216-023-04784-7

Vancouver

Abdel-Aal FAM, Kamel RM, Abdeltawab AA, Mohamed FA, Mohamed AI. Polypyrrole/carbon dot nanocomposite as an electrochemical biosensor for liquid biopsy analysis of tryptophan in the human serum of normal and breast cancer women. Analytical and Bioanalytical Chemistry. 2023;415(20):4985-5001. doi:10.1007/s00216-023-04784-7

BibTeX
@article{AbdelAal2023,
  author = {Abdel-Aal, Fatma A M and Kamel, Rania M and Abdeltawab, Asmaa A and Mohamed, Fardous A and Mohamed, Abdel-Maaboud I},
  title = {Polypyrrole/carbon dot nanocomposite as an electrochemical biosensor for liquid biopsy analysis of tryptophan in the human serum of normal and breast cancer women},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2023},
  volume = {415},
  number = {20},
  pages = {4985--5001},
  doi = {10.1007/s00216-023-04784-7}
}
Kostenlos starten →