EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intensity-Based Camera Setup for Refractometric and Biomolecular Sensing with a Photonic Crystal Microfluidic Chip

Fabio Aldo Kraft, Stefanie Lehmann iD, Carmela Di Maria, Leonie Joksch, Stefanie Fitschen-Östern, Sabine Fuchs iD, Francesco Dell'Olio iD, Martina Gerken iD

Biosensors · 27.06.2023 · 13 (7) · 687

DOI: 10.3390/bios13070687 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 27.06.2023. Verfasst von Fabio Aldo Kraft und 7 weiteren Autor:innen. Beteiligte Einrichtung: Integrated Systems and Photonics, Faculty of Engineering, Kiel University, 24118 Kiel, Germany. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Federal Ministry of Economic Affairs and Climate Action (BMWK), Federal Ministry of Economic Affairs and Climate Action (BMWK).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Label-free sensing is a promising approach for point-of-care testing devices. Among optical transducers, photonic crystal slabs (PCSs) have positioned themselves as an inexpensive yet versatile platform for label-free biosensing. A spectral resonance shift is observed upon biomolecular binding to the functionalized surface. Commonly, a PCS is read out by a spectrometer. Alternatively, the spectral shift may be translated into an intensity change by tailoring the system response. Intensity-based camera setups (IBCS) are of interest as they mitigate the need for postprocessing, enable spatial sampling, and have moderate hardware requirements. However, they exhibit modest performance compared with spectrometric approaches. Here, we show an increase of the sensitivity and limit of detection (LOD) of an IBCS by employing a sharp-edged cut-off filter to optimize the system response. We report an increase of the LOD from (7.1 ± 1.3) × 10−4 RIU to (3.2 ± 0.7) × 10−5 RIU. We discuss the influence of the region of interest (ROI) size on the achievable LOD. We fabricated a biochip by combining a microfluidic and a PCS and demonstrated autonomous transport. We analyzed the performance via refractive index steps and the biosensing ability via diluted glutathione S-transferase (GST) antibodies (1:250). In addition, we illustrate the speed of detection and demonstrate the advantage of the additional spatial information by detecting streptavidin (2.9 µg/mL). Finally, we present the detection of immunoglobulin G (IgG) from whole blood as a possible basis for point-of-care devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMicrofluidicsOptics and PhotonicsRefractometryLimit of Detection

Stichwörter der Autor:innen

biochiplabel-freemicrofluidicsphotonic crystal slabpoint-of-care

Autor:innen und Institutionen

  • Integrated Systems and Photonics, Faculty of Engineering, Kiel University, 24118 Kiel, Germany.
  • Kiel Nano, Surface and Interface Science KiNSIS, Kiel University, 24118 Kiel, Germany.
  • Department of Electrical and Information Engineering, Polytechnic University of Bari, 70126 Bari, Italy.
  • Experimental Trauma Surgery, Department of Trauma Surgery and Orthopedics, University Medical Center Schleswig-Holstein, Kiel University, 24105 Kiel, Germany.

ORCID-Profile: Stefanie Lehmann, Sabine Fuchs, Francesco Dell'Olio, Martina Gerken

Förderung

  • German Federal Ministry of Economic Affairs and Climate Action (BMWK)
  • Federal Ministry of Economic Affairs and Climate Action (BMWK)

Zitieren

APA

Kraft, F. A., Lehmann, S., Di Maria, C., Joksch, L., Fitschen-Östern, S., Fuchs, S., Dell'Olio, F., & Gerken, M. (2023). Intensity-Based Camera Setup for Refractometric and Biomolecular Sensing with a Photonic Crystal Microfluidic Chip. Biosensors, 13(7), 687. https://doi.org/10.3390/bios13070687

Vancouver

Kraft FA, Lehmann S, Di Maria C, Joksch L, Fitschen-Östern S, Fuchs S, et al. Intensity-Based Camera Setup for Refractometric and Biomolecular Sensing with a Photonic Crystal Microfluidic Chip. Biosensors. 2023;13(7):687. doi:10.3390/bios13070687

BibTeX
@article{Kraft2023,
  author = {Kraft, Fabio Aldo and Lehmann, Stefanie and Di Maria, Carmela and Joksch, Leonie and Fitschen-Östern, Stefanie and Fuchs, Sabine and Dell'Olio, Francesco and Gerken, Martina},
  title = {Intensity-Based Camera Setup for Refractometric and Biomolecular Sensing with a Photonic Crystal Microfluidic Chip},
  journal = {Biosensors},
  year = {2023},
  volume = {13},
  number = {7},
  pages = {687},
  doi = {10.3390/bios13070687}
}
Kostenlos starten →