Nickel Oxy-Hydroxy/Multi-Wall Carbon Nanotubes Film Coupled with a 3D-Printed Device as a Nonenzymatic Glucose Sensor
Biosensors · 2023
DOI: 10.3390/bios13060646 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Murillo N T Silva und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-902, MG, Brazil. Hauptthemen laut MEDLINE: Nanotubes, Carbon. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeicoamento de Pessoal de Nível Superior, National Council for Scientific and Technological Development, Fundação de Amparo à Pesquisa do Estado de Minas Gerais.
Abstract (Originalsprache)
A rapid and simple method for the amperometric determination of glucose using a nanocomposite film of nickel oxyhydroxide and multi-walled carbon nanotube (MWCNTs) was evaluated. The NiHCF)/MWCNT electrode film was fabricated using the liquid–liquid interface method, and it was used as a precursor for the electrochemical synthesis of nickel oxy-hydroxy (Ni(OH)2/NiOOH/MWCNT). The interaction between nickel oxy-hydroxy and the MWCNTs provided a film that is stable over the electrode surface, with high surface area and excellent conductivity. The nanocomposite presented an excellent electrocatalytic activity for the oxidation of glucose in an alkaline medium. The sensitivity of the sensor was found to be 0.0561 μA μmol L−1, and a linear range from 0.1 to 150 μmol L−1 was obtained, with a good limit of detection (0.030 μmol L−1). The electrode exhibits a fast response (150 injections h−1) and a sensitive catalytic performance, which may be due to the high conductivity of MWCNT and the increased active surface area of the electrode. Additionally, a minimal difference in the slopes for ascending (0.0561 µA µmol L−1) and descending (0.0531 µA µmol L−1) was observed. Moreover, the sensor was applied to the detection of glucose in artificial plasma blood samples, achieving values of 89 to 98% of recovery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia 38400-902, MG, Brazil.
ORCID-Profile: Murillo N T Silva, Eduardo M Richter, Rodrigo A A Munoz
Förderung
- Coordenação de Aperfeicoamento de Pessoal de Nível Superior
- National Council for Scientific and Technological Development
- Fundação de Amparo à Pesquisa do Estado de Minas Gerais
- CAPES
- FAPEMIG
- FINEP
- CNPq
- Institute of Science and Technology (INCT) in Carbon Nanomaterials and INCT in Bioanalytics
Zitieren
APA
Silva, M. N. T., Rocha, R. G., Richter, E. M., Munoz, R. A. A., & Nossol, E. (2023). Nickel Oxy-Hydroxy/Multi-Wall Carbon Nanotubes Film Coupled with a 3D-Printed Device as a Nonenzymatic Glucose Sensor. Biosensors. https://doi.org/10.3390/bios13060646
Vancouver
Silva MNT, Rocha RG, Richter EM, Munoz RAA, Nossol E. Nickel Oxy-Hydroxy/Multi-Wall Carbon Nanotubes Film Coupled with a 3D-Printed Device as a Nonenzymatic Glucose Sensor. Biosensors. 2023. doi:10.3390/bios13060646
BibTeX
@article{Silva2023,
author = {Silva, Murillo N T and Rocha, Raquel G and Richter, Eduardo M and Munoz, Rodrigo A A and Nossol, Edson},
title = {Nickel Oxy-Hydroxy/Multi-Wall Carbon Nanotubes Film Coupled with a 3D-Printed Device as a Nonenzymatic Glucose Sensor},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13060646}
}
EUVIMED