Tablet-Based Wearable Patch Sensor Design for Continuous Cardiovascular System Monitoring in Postoperative Settings
Biosensors · 2023
DOI: 10.3390/bios13060615 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Nourelhuda Mohamed und 5 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Science and Engineering Department, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea. Hauptthemen laut MEDLINE: Cardiovascular System, Wearable Electronic Devices. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Health Industry Development Institute, Ministry of Health and Welfare, Republic of Korea, GIST.
Abstract (Originalsprache)
Meticulous monitoring for cardiovascular systems is important for postoperative patients in postanesthesia or the intensive care unit. The continuous auscultation of heart and lung sounds can provide a valuable information for patient safety. Although numerous research projects have proposed the design of continuous cardiopulmonary monitoring devices, they primarily focused on the auscultation of heart and lung sounds and mostly served as screening tools. However, there is a lack of devices that could continuously display and monitor the derived cardiopulmonary parameters. This study presents a novel approach to address this need by proposing a bedside monitoring system that utilizes a lightweight and wearable patch sensor for continuous cardiovascular system monitoring. The heart and lung sounds were collected using a chest stethoscope and microphones, and a developed adaptive noise cancellation algorithm was implemented to remove the background noise corrupted with those sounds. Additionally, a short-distance ECG signal was acquired using electrodes and a high precision analog front end. A high-speed processing microcontroller was used to allow real-time data acquisition, processing, and display. A dedicated tablet-based software was developed to display the acquired signal waveforms and the processed cardiovascular parameters. A significant contribution of this work is the seamless integration of continuous auscultation and ECG signal acquisition, thereby enabling the real-time monitoring of cardiovascular parameters. The wearability and lightweight design of the system were achieved through the use of rigid–flex PCBs, which ensured patient comfort and ease of use. The system provides a high-quality signal acquisition and real-time monitoring of the cardiovascular parameters, thus proving its potential as a health monitoring tool.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Science and Engineering Department, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea.
- Biomedical Engineering Research Center, Asan Institute for Life Science, Asan Medical Center, Seoul 05505, Republic of Korea.
- Department of Anesthesiology and Pain Medicine, Asan Medical Center, Seoul 05505, Republic of Korea.
ORCID-Profile: Nourelhuda Mohamed, Hyun-Seok Kim, Manal Mohamed, Jae Gwan Kim
Förderung
- Korea Health Industry Development Institute
- Ministry of Health and Welfare, Republic of Korea
- GIST
Zitieren
APA
Mohamed, N., Kim, H. S., Mohamed, M., Kang, K. M., Kim, S. H., & Kim, J. G. (2023). Tablet-Based Wearable Patch Sensor Design for Continuous Cardiovascular System Monitoring in Postoperative Settings. Biosensors. https://doi.org/10.3390/bios13060615
Vancouver
Mohamed N, Kim HS, Mohamed M, Kang KM, Kim SH, Kim JG. Tablet-Based Wearable Patch Sensor Design for Continuous Cardiovascular System Monitoring in Postoperative Settings. Biosensors. 2023. doi:10.3390/bios13060615
BibTeX
@article{Mohamed2023,
author = {Mohamed, Nourelhuda and Kim, Hyun-Seok and Mohamed, Manal and Kang, Kyu-Min and Kim, Sung-Hoon and Kim, Jae Gwan},
title = {Tablet-Based Wearable Patch Sensor Design for Continuous Cardiovascular System Monitoring in Postoperative Settings},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13060615}
}
EUVIMED