Oscillatory-Flow PCR Microfluidic Chip Driven by Low Speed Biaxial Centrifugation
Biosensors · 2023
DOI: 10.3390/bios13050555 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Yunlong Fan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, the Ministry of Industry and Information Technology, 5 South Zhon…. Hauptthemen laut MEDLINE: Microfluidics, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Defense Industrial Technology Development Program.
Abstract (Originalsprache)
PCR is indispensable in basic science and biotechnology for in-orbit life science research. However, manpower and resources are limited in space. To address the constraints of in-orbit PCR, we proposed an oscillatory-flow PCR technique based on biaxial centrifugation. Oscillatory-flow PCR remarkably reduces the power requirements of the PCR process and has a relatively high ramp rate. A microfluidic chip that could perform dispensing, volume correction, and oscillatory-flow PCR of four samples simultaneously using biaxial centrifugation was designed. An automatic biaxial centrifugation device was designed and assembled to validate the biaxial centrifugation oscillatory-flow PCR. Simulation analysis and experimental tests indicated that the device could perform fully automated PCR amplification of four samples in one hour, with a ramp rate of 4.4 ∘C/s and average power consumption of less than 30 W. The PCR results were consistent with those obtained using conventional PCR equipment. Air bubbles generated during amplification were removed by oscillation. The chip and device realized a low-power, miniaturized, and fast PCR method under microgravity conditions, indicating good space application prospects and potential for higher throughput and extension to qPCR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, the Ministry of Industry and Information Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China 2 Beijing Key…
- Beijing Key Laboratory for Separation and Analysis in Biomedicine and Pharmaceuticals, School of Life Sciences, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing 100081, China.
ORCID-Profile: Xiaoqiong Li
Förderung
- Defense Industrial Technology Development Program
Zitieren
APA
Fan, Y., Dai, R., Lu, S., Liu, X., Zhou, T., Yang, C., Hu, X., Lv, X., & Li, X. (2023). Oscillatory-Flow PCR Microfluidic Chip Driven by Low Speed Biaxial Centrifugation. Biosensors. https://doi.org/10.3390/bios13050555
Vancouver
Fan Y, Dai R, Lu S, Liu X, Zhou T, Yang C, et al. Oscillatory-Flow PCR Microfluidic Chip Driven by Low Speed Biaxial Centrifugation. Biosensors. 2023. doi:10.3390/bios13050555
BibTeX
@article{Fan2023,
author = {Fan, Yunlong and Dai, Rongji and Lu, Shuyu and Liu, Xinyu and Zhou, Taiyan and Yang, Chunhua and Hu, Xiaoming and Lv, Xuefei and Li, Xiaoqiong},
title = {Oscillatory-Flow PCR Microfluidic Chip Driven by Low Speed Biaxial Centrifugation},
journal = {Biosensors},
year = {2023},
doi = {10.3390/bios13050555}
}
EUVIMED