EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A New Multi-Axial Functional Stress Analysis Assessing the Longevity of a Ti-6Al-4V Dental Implant Abutment Screw

Ghada H Naguib, Ahmed O Abougazia iD, Lulwa E Al-Turki, Hisham A Mously, Abou Bakr Hossam Hashem, Abdulghani I Mira iD, Osama A Qutub iD, Abdulelah M Binmahfooz, Afaf A Almabadi iD, Mohamed T Hamed

Biomimetics · 12.11.2024 · 9 (11) · 689

DOI: 10.3390/biomimetics9110689 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomimetics, online erschienen am 12.11.2024. Verfasst von Ghada H Naguib und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80209, Jeddah 21589, Saudi Arabia. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 155 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the impact of tightening torque (preload) and the friction coefficient on stress generation and fatigue resistance of a Ti-6Al-4V abutment screw with an internal hexagonal connection under dynamic multi-axial masticatory loads in high-cycle fatigue (HCF) conditions. A three-dimensional model of the implant–abutment assembly was simulated using ANSYS Workbench 16.2 computer aided engineering software with chewing forces ranging from 300 N to 1000 N, evaluated over 1.35 × 107 cycles, simulating 15 years of service. Results indicate that the healthy range of normal to maximal mastication forces (300–550 N) preserved the screw’s structural integrity, while higher loads (≥800 N) exceeded the Ti-6Al-4V alloy’s yield strength, indicating a risk of plastic deformation under extreme conditions. Stress peaked near the end of the occluding phase (206.5 ms), marking a critical temporal point for fatigue accumulation. Optimizing the friction coefficient (0.5 µ) and preload management improved stress distribution, minimized fatigue damage, and ensured joint stability. Masticatory forces up to 550 N were well within the abutment screw’s capacity to sustain extended service life and maintain its elastic behavior.

Schlagwörter

Stichwörter der Autor:innen

Ti-6Al-4V alloyabutment screwbiomaterialsdental implant therapydynamic loadingfatigue damage parameterfatigue life predictionfinite element analysis (FEA)preloadprothesis designstress distribution

Autor:innen und Institutionen

  • Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80209, Jeddah 21589, Saudi Arabia.
  • Department of Oral Biology, Cairo University School of Dentistry, Cairo 12613, Egypt.
  • Independent Researcher, Giza 12573, Egypt.
  • Department of Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80209, Jeddah 21589, Saudi Arabia.
  • Dental Department, Research Institute of Ophthalmology, Oula, Giza District, Giza 12557, Egypt.
  • Department of Restorative Dentistry, King Abdulaziz University, P.O. Box 80209, Jeddah 21589, Saudi Arabia.

ORCID-Profile: Ahmed O Abougazia, Abdulghani I Mira, Osama A Qutub, Afaf A Almabadi

Zitieren

APA

Naguib, G. H., Abougazia, A. O., Al-Turki, L. E., Mously, H. A., Hashem, A. B. H., Mira, A. I., Qutub, O. A., Binmahfooz, A. M., Almabadi, A. A., & Hamed, M. T. (2024). A New Multi-Axial Functional Stress Analysis Assessing the Longevity of a Ti-6Al-4V Dental Implant Abutment Screw. Biomimetics, 9(11), 689. https://doi.org/10.3390/biomimetics9110689

Vancouver

Naguib GH, Abougazia AO, Al-Turki LE, Mously HA, Hashem ABH, Mira AI, et al. A New Multi-Axial Functional Stress Analysis Assessing the Longevity of a Ti-6Al-4V Dental Implant Abutment Screw. Biomimetics. 2024;9(11):689. doi:10.3390/biomimetics9110689

BibTeX
@article{Naguib2024,
  author = {Naguib, Ghada H and Abougazia, Ahmed O and Al-Turki, Lulwa E and Mously, Hisham A and Hashem, Abou Bakr Hossam and Mira, Abdulghani I and Qutub, Osama A and Binmahfooz, Abdulelah M and Almabadi, Afaf A and Hamed, Mohamed T},
  title = {A New Multi-Axial Functional Stress Analysis Assessing the Longevity of a Ti-6Al-4V Dental Implant Abutment Screw},
  journal = {Biomimetics},
  year = {2024},
  volume = {9},
  number = {11},
  pages = {689},
  doi = {10.3390/biomimetics9110689}
}
Kostenlos starten →