EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Composite Viscosity, Cavity Type, and Placement Technique on Microleakage in Stamp Technique Restorations: An In Vitro Study

Ayşenur Yazım iD, Cemile Kedici Alp, Ceyda Sarı

Biomimetics · 01.06.2026 · 11 (6) · 382

DOI: 10.3390/biomimetics11060382 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomimetics, online erschienen am 01.06.2026. Verfasst von Ayşenur Yazım und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, Ankara 06490, Türkiye. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gazi University, Gazi University Scientific Research Projects Coordination Unit.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The biomimetic restoration of occlusal morphology aims to replicate the natural form and function of dental tissues while preserving structural integrity. The stamp technique enables accurate reproduction of occlusal anatomy in posterior restorations; however, the extent to which different composite systems maintain marginal integrity and reduce microleakage when this technique is applied remains unclear. This in vitro study evaluated the microleakage of bulk-fill resin composites with different viscosities applied using the stamp technique. A total of 120 extracted human molars (n = 10 per group) were prepared with standardized Class I and Class II cavities and restored using SonicFill™, VisCalor, or Filtek™ Bulk-Fill composites, applied either in a single or two increments. After thermocycling, specimens were dye-penetrated, sectioned, and analyzed using ImageJ. Data were analyzed by two-way ANOVA and Tukey’s HSD test (p < 0.05). In Class I cavities, occlusal microleakage differed significantly among materials (p = 0.001), with SonicFill™ showing the lowest values. In Class II cavities, gingival microleakage was significantly affected by both material and placement technique (p = 0.001). Incremental placement significantly reduced gingival microleakage for SonicFill™ and Filtek™ Bulk-Fill. Material viscosity and placement strategy influence marginal adaptation under stamp technique conditions. Low-viscosity bulk-fill composites demonstrated improved sealing, while incremental placement enhanced marginal integrity, particularly in Class II cavities.

Schlagwörter

Stichwörter der Autor:innen

biomimetic dentistrybulk-fill compositesmicroleakagestamp technique

Autor:innen und Institutionen

  • Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, Ankara 06490, Türkiye.
  • Department of Restorative Dentistry, Faculty of Dentistry, Istanbul Medipol University, Istanbul 34083, Türkiye.

ORCID-Profile: Ayşenur Yazım

Förderung

  • Gazi University
  • Gazi University Scientific Research Projects Coordination Unit

Zitieren

APA

Yazım, A., Kedici Alp, C., & Sarı, C. (2026). Effect of Composite Viscosity, Cavity Type, and Placement Technique on Microleakage in Stamp Technique Restorations: An In Vitro Study. Biomimetics, 11(6), 382. https://doi.org/10.3390/biomimetics11060382

Vancouver

Yazım A, Kedici Alp C, Sarı C. Effect of Composite Viscosity, Cavity Type, and Placement Technique on Microleakage in Stamp Technique Restorations: An In Vitro Study. Biomimetics. 2026;11(6):382. doi:10.3390/biomimetics11060382

BibTeX
@article{Yazm2026,
  author = {Yazım, Ayşenur and Kedici Alp, Cemile and Sarı, Ceyda},
  title = {Effect of Composite Viscosity, Cavity Type, and Placement Technique on Microleakage in Stamp Technique Restorations: An In Vitro Study},
  journal = {Biomimetics},
  year = {2026},
  volume = {11},
  number = {6},
  pages = {382},
  doi = {10.3390/biomimetics11060382}
}
Kostenlos starten →