Effect of Water Storage on Microleakage of Class II MOD Bulk-fill Resin Composite Restorations: In Vitro Evaluation

Ali Ihsan Alqurashi, Basma Ahmed, Omar Abd El-Maksoud, Ramy Ahmed Wafaie, Salah Hasab Mahmoud

European Journal of Dentistry · 26.02.2026

DOI: 10.1055/s-0046-1816583 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Dentistry, erschienen am 26.02.2026. Verfasst von Ali Ihsan Alqurashi und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Dentistry, Al-Mustaqbal University, Babylon, Iraq. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To evaluate and compare the effect of 6-month water storage on the marginal microleakage of class II MOD cavities restored with two different bulk-fill resin composites (sculptable and no-cap flowable) and a conventional resin composite. A total of 60 sound freshly extracted mandibular molars, each with a standardized class II MOD cavity, were assigned into three main groups according to the restorative material used as follows: bulk-fill resin composite (SimpliShade, Kerr), no-cap flowable bulk-fill resin composite (G-aenial Bulk Injectable, GC), and conventional resin composite (Neo Spectra ST LV, Dentsply Sirona). Each group was further divided into two subgroups (n = 10) based on the water-storage time: 24 hours (immediate) and 6-month water storage (aged). All specimens were thermocycled 5,000 times between 5°C ± 2°C and 55°C ± 2°C, then immersed in 2% basic fuchsin dye for 24 hours. The specimens were longitudinally sectioned, and the amount of dye penetration was evaluated using stereomicroscope under 25× magnification. The results were analyzed by non-parametric Kruskal-Wallis, Mann-Whitney, and Wilcoxon signed-rank tests. The level of significance was set at p

Autor:innen und Institutionen

  • College of Dentistry, Al-Mustaqbal University, Babylon, Iraq.
  • Conservative Dentistry Department, Faculty of Oral and Dental Medicine, Delta University for Science and Technology, Gamasa, Egypt.
  • Faculty of Dentistry, Aqaba Medical Sciences University, Aqaba, Jordan.
  • Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.

Zitieren

APA

Alqurashi, A. I., Ahmed, B., El-Maksoud, O. A., Wafaie, R. A., & Mahmoud, S. H. (2026). Effect of Water Storage on Microleakage of Class II MOD Bulk-fill Resin Composite Restorations: In Vitro Evaluation. European Journal of Dentistry. https://doi.org/10.1055/s-0046-1816583

Vancouver

Alqurashi AI, Ahmed B, El-Maksoud OA, Wafaie RA, Mahmoud SH. Effect of Water Storage on Microleakage of Class II MOD Bulk-fill Resin Composite Restorations: In Vitro Evaluation. European Journal of Dentistry. 2026. doi:10.1055/s-0046-1816583

BibTeX
@article{Alqurashi2026,
  author = {Alqurashi, Ali Ihsan and Ahmed, Basma and El-Maksoud, Omar Abd and Wafaie, Ramy Ahmed and Mahmoud, Salah Hasab},
  title = {Effect of Water Storage on Microleakage of Class II MOD Bulk-fill Resin Composite Restorations: In Vitro Evaluation},
  journal = {European Journal of Dentistry},
  year = {2026},
  doi = {10.1055/s-0046-1816583}
}
Kostenlos starten →