Multimodal Anion-Exchange Resins for Chromatographic Separation of Antibody Aggregates
Biomolecules · 27.05.2026 · 16 (6) · 785
DOI: 10.3390/biom16060785 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomolecules, online erschienen am 27.05.2026. Verfasst von Simona Kotuličová und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biochemical Engineering, Institute of Chemical and Environmental Engineering, Faculty of Chemical and Food Technology, Slo…. Hauptthemen laut MEDLINE: Anion Exchange Resins, Protein Aggregates. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Slovak Research and Development Agency.
Abstract (Originalsprache)
Efficient protein aggregate removal remains a major challenge in downstream bioprocessing because high aggregate clearance must be achieved without compromising monomer yield. Mixed-mode chromatography (MMC) has emerged as a promising approach, offering enhanced selectivity through combined ionic and hydrophobic interactions and salt-tolerant behavior. However, the relative roles of matrix pore accessibility and ligand density remain insufficiently understood. In this study, MMC adsorbents based on 4% and 6% agarose matrices were functionalized with a BMEA ligand. Inverse size-exclusion chromatography revealed that functionalization caused matrix syneresis, increasing dry matter content to 23% and enhancing mechanical rigidity. MMC-Ag4, with a larger mean pore radius (19.1 nm), exhibited a selectivity factor of 2 toward aggregates in static binding experiments, whereas the denser MMC-Ag6 (15.7 nm) showed no selectivity. In column studies using a feed containing 10% aggregates, MMC-Ag4 outperformed the commercial benchmark Capto Adhere, achieving monomer yields of 80–90% at 97–98% purity with salt tolerance up to 300 mM NaCl. These findings indicate that while MMC-Ag6 is limited by pore blockage, the optimized pore accessibility of MMC-Ag4 enables effective aggregate recognition. In conclusion, multimodal adsorbent design must balance ligand density with matrix porosity to ensure high resolution and yield in aggregate removal.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical and Biochemical Engineering, Institute of Chemical and Environmental Engineering, Faculty of Chemical and Food Technology, Slovak University of Technology, Radlinského 9, 812 37 Bratislava, Slovak…
ORCID-Profile: Tomáš Molnár, Milan Polakovič
Förderung
- Slovak Research and Development Agency
Zitieren
APA
Kotuličová, S., Molnár, T., & Polakovič, M. (2026). Multimodal Anion-Exchange Resins for Chromatographic Separation of Antibody Aggregates. Biomolecules, 16(6), 785. https://doi.org/10.3390/biom16060785
Vancouver
Kotuličová S, Molnár T, Polakovič M. Multimodal Anion-Exchange Resins for Chromatographic Separation of Antibody Aggregates. Biomolecules. 2026;16(6):785. doi:10.3390/biom16060785
BibTeX
@article{Kotuliov2026,
author = {Kotuličová, Simona and Molnár, Tomáš and Polakovič, Milan},
title = {Multimodal Anion-Exchange Resins for Chromatographic Separation of Antibody Aggregates},
journal = {Biomolecules},
year = {2026},
volume = {16},
number = {6},
pages = {785},
doi = {10.3390/biom16060785}
}
EUVIMED