Fachartikel in der Zeitschrift Journal of Chromatography A, 2025. Verfasst von Eric Denbaum und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry and Biophysics and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 1218…. Hauptthemen laut MEDLINE: Cation Exchange Resins, Anion Exchange Resins. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Biorad Inc.
Abstract (Originalsprache)
This paper employs a previously developed high-throughput parallel batch adsorption screen with sequential salt step increases to rapidly investigate a set of prototype multimodal anion- (MMA) and cation-exchange (MMC) resins. Experiments were carried out using a model protein library with varying charge and hydrophobic characteristics at several pH conditions. Partition coefficients were calculated from the batch chromatograms and fed into a column (linear salt gradient) simulator to determine peak first moments (elution salt concentration). These results enabled the calculation of one-resin separability scores, quantifying each resin's ability, at a given pH, to separate all proteins in the library. Additionally, a clustering analysis grouped resins with similar chromatographic behavior, revealing correlations between resin chemistry (e.g., functional groups and geometric presentation) and protein elution patterns. Finally, the first moment data sets were used to calculate two-resin separability scores, the ability of two resins to synergistically separate the entire set of proteins from each other. These results indicated that MMC resins containing phthalimide-based moieties in concert with guanidine-containing MMA resins were particularly useful when used in concert. Overall, the presented approach is shown to be an enabling technology for rapidly screening large numbers of ligands and operating conditions for discovery of next-generation chromatographic resins.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biochemistry and Biophysics and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, USA.
- Department of Chemical and Biological Engineering and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, USA.
- Bio-Rad Laboratories, Hercules, CA 94547, USA.
- Department of Chemical and Biological Engineering and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, USA. Electronic address: crames@rpi.edu.
Förderung
- Biorad Inc
Zitieren
APA
Denbaum, E., Diaz, M. A. G., Altern, S. H., Belisle, C., Snyder, M. A., & Cramer, S. M. (2025). Evaluation of prototype multimodal resins using chromatographic separability. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2025.465723
Vancouver
Denbaum E, Diaz MAG, Altern SH, Belisle C, Snyder MA, Cramer SM. Evaluation of prototype multimodal resins using chromatographic separability. Journal of Chromatography A. 2025. doi:10.1016/j.chroma.2025.465723
BibTeX
@article{Denbaum2025,
author = {Denbaum, Eric and Diaz, Mario A Gutierrez and Altern, Scott H and Belisle, Chris and Snyder, Mark A and Cramer, Steven M},
title = {Evaluation of prototype multimodal resins using chromatographic separability},
journal = {Journal of Chromatography A},
year = {2025},
doi = {10.1016/j.chroma.2025.465723}
}
EUVIMED