Initial Force Expression of Different Clear Aligner Systems in a Simulated Maxillary Canine Distalization Model with Lateral Incisor Agenesis: An In Vitro Comparative Study

Alessio Verdecchia, Samuele Avolese, Andrea Tancredi Lugas, Cristina Bignardi, Mara Terzini, Claudia Dettori, Enrico Spinas, Teresa Cobo, Nicola Scotti

Bioengineering · 08.11.2026 · 13 (11) · 1326

DOI: 10.3390/bioengineering13111326 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 08.11.2026. Verfasst von Alessio Verdecchia und 8 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Turin.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This in vitro study compared initial force release by different clear aligner systems during simulated maxillary canine distalization with lateral incisor agenesis and evaluated attachment effects.

Methods

Five aligner systems were tested: SmartTrackTM (Invisalign®, Align Technology Inc., Santa Clara, CA, USA), TruGENTM (Spark®, Ormco Corporation, Brea, CA, USA), Essix® (SureSmile®, Dentsply Sirona Inc., Charlotte, NC, USA), MasterControl S (Angel Aligner®, Angelalign Technology Inc., Shanghai, China), and a directly 3D-printed aligner fabricated with TC-85 DAC resin (Graphy®, Graphy Inc., Seoul, Republic of Korea). Ten identical aligners per configuration were tested for 1 h at 37 °C in physiological solution. The ElectroForce® system measured the translational force at the canine’s root-level support. Data were analyzed using descriptive statistics and two-way ANOVA.

Results

TruGENTM with attachments generated the highest mean force (1.25 N), followed by SmartTrackTM (0.61 N), Essix® (0.42 N), MasterControl S (0.39 N), and TC-85 DAC resin (0.01 N). Without attachments, forces were minimal for all systems. Force decay was observed in groups expressing measurable forces.

Conclusions

Attachments enabled measurable translational force components in thermoformed systems. Force expression differed among systems, while TC-85 DAC resin produced negligible forces with or without attachments under experimental conditions. Further clinical validation is warranted.

Förderung

  • University of Turin

Zitieren

APA

Verdecchia, A., Avolese, S., Lugas, A. T., Bignardi, C., Terzini, M., Dettori, C., Spinas, E., Cobo, T., & Scotti, N. (2026). Initial Force Expression of Different Clear Aligner Systems in a Simulated Maxillary Canine Distalization Model with Lateral Incisor Agenesis: An In Vitro Comparative Study. Bioengineering, 13(11), 1326. https://doi.org/10.3390/bioengineering13111326

Vancouver

Verdecchia A, Avolese S, Lugas AT, Bignardi C, Terzini M, Dettori C, et al. Initial Force Expression of Different Clear Aligner Systems in a Simulated Maxillary Canine Distalization Model with Lateral Incisor Agenesis: An In Vitro Comparative Study. Bioengineering. 2026;13(11):1326. doi:10.3390/bioengineering13111326

BibTeX
@article{Verdecchia2026,
  author = {Verdecchia, Alessio and Avolese, Samuele and Lugas, Andrea Tancredi and Bignardi, Cristina and Terzini, Mara and Dettori, Claudia and Spinas, Enrico and Cobo, Teresa and Scotti, Nicola},
  title = {Initial Force Expression of Different Clear Aligner Systems in a Simulated Maxillary Canine Distalization Model with Lateral Incisor Agenesis: An In Vitro Comparative Study},
  journal = {Bioengineering},
  year = {2026},
  volume = {13},
  number = {11},
  pages = {1326},
  doi = {10.3390/bioengineering13111326}
}
Kostenlos starten →