Factors Associated With Maxillary Incisor Crown Torque Expression in Non‐Extraction Clear Aligner Treatment
Orthodontics & Craniofacial Research · 2026-12 · 29 (6) · 1017-1024
DOI: 10.1111/ocr.70149 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthodontics & Craniofacial Research, online erschienen am 29.05.2026. Verfasst von Zixin Miao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Shenzhen People's Hospital, Shenzhen, Guangdong, China. Hauptthemen laut MEDLINE: Incisor, Tooth Movement Techniques, Tooth Crown, Orthodontic Appliances, Removable. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Sanming Project of Medicine in Shenzen Municipality.
Abstract (Originalsprache)
Objectives
To quantitatively assess the accuracy of maxillary incisor torque expression and identify its influencing factors in non‐extraction cases treated with Invisalign aligners. Materials and Methods Records of 50 adult patients treated with Invisalign aligners at a single tertiary stomatology center between June 2019 and December 2024 were retrospectively analysed. A total of 144 maxillary incisors were included. Digital models from pretreatment (T0), after staged treatment (T1), and predicted posttreatment (T2) were obtained from ClinCheck. Torque values were measured on all models using Geomagic Control X software to calculate the torque expression rate (TER). Predicted and achieved torque changes were compared using paired t ‐tests. Multiple linear regression was employed to identify significant predictors of TER.
Results
The overall TER for maxillary incisors was 48.1%. On average, the achieved torque change was significantly less than predicted, with a mean difference of 4.25° (95% CI, 3.21°–5.30°; p < 0.05). Under‐expression of the planned torque was observed in 111 incisors (77.1%). Regression analysis identified planned crown torque and vertical skeletal pattern as independent predictors of TER ( p < 0.05). For each 1° increase in planned torque, TER increased by 5.92%. A high‐angle vertical pattern was associated with an 18.45% reduction in TER compared with other vertical patterns.
Conclusions
Torque expression of maxillary incisors with clear aligners was limited. Planned crown torque and vertical skeletal pattern were significant influencing factors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, Shenzhen People's Hospital, Shenzhen, Guangdong, China.
- Department of Orthodontics, School of Stomatology, Jinan University, Guangzhou, Guangdong, China.
- Luohu People's Hospital, Shenzhen, Guangdong, China.
- Shiyan People's Hospital, Bao'an District, Shenzhen, Guangdong, China.
- Elite Huizhou Dental Clinic, Huizhou, Guangdong, China.
ORCID-Profile: Zixin Miao
Förderung
- Sanming Project of Medicine in Shenzen Municipality
Zitieren
APA
Miao, Z., Li, M., Zheng, H., Shen, C. L., Chen, Z., & Wei, X. (2026). Factors Associated With Maxillary Incisor Crown Torque Expression in Non‐Extraction Clear Aligner Treatment. Orthodontics & Craniofacial Research, 29(6), 1017-1024. https://doi.org/10.1111/ocr.70149
Vancouver
Miao Z, Li M, Zheng H, Shen CL, Chen Z, Wei X. Factors Associated With Maxillary Incisor Crown Torque Expression in Non‐Extraction Clear Aligner Treatment. Orthodontics & Craniofacial Research. 2026;29(6):1017-1024. doi:10.1111/ocr.70149
BibTeX
@article{Miao2026,
author = {Miao, Zixin and Li, Mohan and Zheng, Henan and Shen, Chia-Ling and Chen, Zhifa and Wei, Xiaoxia},
title = {Factors Associated With Maxillary Incisor Crown Torque Expression in Non‐Extraction Clear Aligner Treatment},
journal = {Orthodontics & Craniofacial Research},
year = {2026},
volume = {29},
number = {6},
pages = {1017--1024},
doi = {10.1111/ocr.70149}
}