Biomechanical Evaluation of Force Loss and Simulated Tooth Movement in Maxillary Orthodontic Mesial Sliders: An In Vitro Pilot Study
Bioengineering · 2026-08-21 · 13 (8) · 948
DOI: 10.3390/bioengineering13080948 ↗At a glance
Journal article in Bioengineering, published online on 2026-08-21. Written by Carolien A J Scheurer and 7 co-authors. Institution: Department of Orthodontics, Medical Faculty Heidelberg, Heidelberg University, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany. 40 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Skeletal-anchored mesial sliders are increasingly used for molar mesialization, yet their mechanical behavior has not been compared under standardized conditions. This in vitro pilot study evaluated four slider designs (BENEfit® Beneslider [BB], TADMAN Beneslider [TB], IZE Slider [IO; OrthoLIZE GmbH], Slider on Minipin [SO; OrthoLIZE GmbH]), each combined with elastic chains (-C) or NiTi springs (-S), to characterize force loss, mesial movement, and associated mechanical side effects using an experimental biomechanical measurement system. Using repeated measurements on one specimen with 1 N of applied force, three-dimensional tooth movements were recorded across 200 simulation steps per run. The sliders showed design-dependent mechanical patterns: IO sliders produced the smallest sagittal movements (IO-C: −0.84 mm [0.05], IO-S: −0.79 mm [0.02]) and the highest force loss (IO-C: 88.1% [2.1], IO-S: 89.8% [0.3]), whereas BB-S and TB-S generated larger mesialization distances (BB-S: −3.55 mm [0.53], TB-S: −3.46 mm [0.08]) with lower force loss (BB-S: 42.8% [9.2], TB-S: 21.1% [2.9]). Translational deviations remained small, while rotational effects were more pronounced. These findings represent mechanical tendencies of the tested configurations under idealized conditions and do not account for biological variability, periodontal compliance, or patient-specific factors. As such, the results cannot be generalized to clinical performance but provide preliminary reference data. Expanded investigations using multiple specimens, biological modeling, or finite element analysis will be necessary to determine how these mechanical patterns translate into clinical tooth movement.
Subjects
Author keywords
Authors and institutions
- Department of Orthodontics, Medical Faculty Heidelberg, Heidelberg University, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
- Zahnarztteam Hamm, Private Practice, Bockum-Hövel, 59075 Hamm, Germany.
- Oral Technology, University Hospital Bonn, 53111 Bonn, Germany.
- Department of Oral and Maxillofacial Surgery, Medical Faculty Heidelberg, Heidelberg University, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
ORCID profiles: Carolien A J Scheurer, Delia B Rieken, Christoph Bourauel, Ludger Keilig, Christopher J Lux, Juliana Marie-Kristine Mielke
Cite
APA
Scheurer, C. A. J., Dommack, L. H., Rieken, D. B., Bourauel, C., Keilig, L., Scheurer, M. P., Lux, C. J., & Mielke, J. M. (2026). Biomechanical Evaluation of Force Loss and Simulated Tooth Movement in Maxillary Orthodontic Mesial Sliders: An In Vitro Pilot Study. Bioengineering, 13(8), 948. https://doi.org/10.3390/bioengineering13080948
Vancouver
Scheurer CAJ, Dommack LH, Rieken DB, Bourauel C, Keilig L, Scheurer MP, et al. Biomechanical Evaluation of Force Loss and Simulated Tooth Movement in Maxillary Orthodontic Mesial Sliders: An In Vitro Pilot Study. Bioengineering. 2026;13(8):948. doi:10.3390/bioengineering13080948
BibTeX
@article{Scheurer2026,
author = {Scheurer, Carolien A J and Dommack, Luise H and Rieken, Delia B and Bourauel, Christoph and Keilig, Ludger and Scheurer, Mats Philipp and Lux, Christopher J and Mielke, Juliana Marie-Kristine},
title = {Biomechanical Evaluation of Force Loss and Simulated Tooth Movement in Maxillary Orthodontic Mesial Sliders: An In Vitro Pilot Study},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {8},
pages = {948},
doi = {10.3390/bioengineering13080948}
}
EUVIMED