Improved SNR and Image Quality of Pediatric MRI with a Shape Conforming High-Density Posterior Cushion Coil
Bioengineering · 30.07.2026 · 13 (8) · 881
DOI: 10.3390/bioengineering13080881 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering, online erschienen am 30.07.2026. Verfasst von Terrence Jao und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NHLBI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
A high-density posterior cushion coil (HDPCC) can improve the SNR in pediatric MRI by conforming to the body and minimizing distance to the imaged volume when compared to a conventional rigid built-in table coil array. Posterior coil arrays built into MRI tables are mainstays but provide suboptimal performance in pediatric imaging due to their distance from the imaged volume and lower coil density. Our goal is to improve pediatric MRI by constructing a prototype 30-channel high-density posterior cushion coil (HDPCC) incorporated into a padded cushion. Twenty-five pediatric patients were scanned with the HDPCC, and twenty-five pediatric controls served as the comparison group using standard coils. Two radiologists graded image quality on a 5-point scale. SNR was measured in the right paraspinal musculature and the liver. All images obtained with the HDPCC were diagnostic (mean score 4.13/5). SNR in the superficial tissues of the paraspinal musculature was 34% higher with the HDPCC than with standard coils, while SNR in the deeper tissues of the liver was statistically similar between the two coils. HDPCC yields improved the signal-to-noise ratio in phantoms and pediatric study participants by conforming to the body.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA.
- General Electric Healthcare, Aurora, OH 44202, USA.
- Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA.
ORCID-Profile: Terrence Jao, Jana Vincent, Fraser Robb, Shreyas Vasanawala
Förderung
- NIBIB NIH HHS
- NHLBI NIH HHS
- National Institutes of Health
Zitieren
APA
Jao, T., Jayapal, P., Vincent, J., Pauly, J., Stack, C., Taracila, V., Robb, F., Grafendorfer, T., Stickle, Y. J., Giancola, M., Follante, C. K., Scott, G., Vasanawala, S., & Syed, A. B. (2026). Improved SNR and Image Quality of Pediatric MRI with a Shape Conforming High-Density Posterior Cushion Coil. Bioengineering, 13(8), 881. https://doi.org/10.3390/bioengineering13080881
Vancouver
Jao T, Jayapal P, Vincent J, Pauly J, Stack C, Taracila V, et al. Improved SNR and Image Quality of Pediatric MRI with a Shape Conforming High-Density Posterior Cushion Coil. Bioengineering. 2026;13(8):881. doi:10.3390/bioengineering13080881
BibTeX
@article{Jao2026,
author = {Jao, Terrence and Jayapal, Praveen and Vincent, Jana and Pauly, John and Stack, Ceara and Taracila, Victor and Robb, Fraser and Grafendorfer, Thomas and Stickle, Yun Jeong and Giancola, Mark and Follante, Clyve Konrad and Scott, Greig and Vasanawala, Shreyas and Syed, Ali B},
title = {Improved SNR and Image Quality of Pediatric MRI with a Shape Conforming High-Density Posterior Cushion Coil},
journal = {Bioengineering},
year = {2026},
volume = {13},
number = {8},
pages = {881},
doi = {10.3390/bioengineering13080881}
}
EUVIMED